background image

 

 

15

 

 
 
 

 

 
LUBRIFICATION 

Air tools require regular lubrication throughout the life of the tool. The air motor and bearing use 
compressed air to power the tool. Because moisture in compressed air will rust the air motor, you 
must lubricate the motor daily. An inline oiler is recommended. 
 

To lubricate the air motor manually: 
 

 

Disconnect the tool from the air supply holding it so the air inlet faces up.

 

 

Depress the trigger and place one to two drops of air tool oil in the air inlet. 

 

Connect the tool to an air source, cover the exhaust end with a towel and run for a few seconds. 

 

Every 3 or 4 hours of operation, oiling is necessary. 

 

Do not lubricate tools with flammable or volatile liquids such as kerosene, diesel or jet fuel. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

ATTENTION 

ALWAYS DISCONNECT AIR SUPPLY BEFORE LUBRICATING, 
INSTALLING, REMOVING OR ADJUSTING THE TOOL 

ATTENTION 

Any excess oil in the motor is  immediately expelled from the exhaust port. Always direct 
exhaust port away from people or objects. 

5.

 

MAINTENANCE 

Summary of Contents for FGA 334/AN

Page 1: ...9 FGA 334 AN SAFETY MANUAL AND INSTRUCTION MANUAL AIR GRINDER Rev 112017 The reproduction of this document even in partial form is prohibited without the Fasangas S r l authorization ...

Page 2: ...GENERAL WARNINGS 2 TECHNICAL FEATURES OF THE TOOL 3 IMPORTANT SAFETY INSTRUCTION 4 FUNCTIONAL INSTRUCTIONS 5 MAINTENANCE 6 TROUBLESHOOT 7 DISPOSAL INFORMATIONS 8 EC DECLARATION OF CONFORMITY 9 WARRANTY INDEX ...

Page 3: ...example the un observance of the safety instruction the use of no original accessories and operation not authorized on the product MODEL FGA 334 AN TYPE AIR DIE GRINDER WEIGHT 0 50 kg 1 1 lb LENGHT 160 mm COMPRESSED AIR Max working pressure 6 2 BAR 90 PSI Raccommanded pressure 6 2 BAR 90 PSI Air consumption at 90 PSI 2 6 CFM 74 L min Free speed 20000 rpm Min hose size NOISE VALUES EN ISO 15744 200...

Page 4: ...ve equipment mask in accordance with current standards DPI Dir 89 686 EEC Abrasive tools such as grinders and sanders generate dust and abrasive materials which can be harmful to human lungs and respiratory systems Some materials such as adhesives and tar contain chemicals whose vapors could cause serious injury with prolonged exposure Avoid prolonged and continuous use of the tool Prolonged expos...

Page 5: ...ries to the tool Never operate tool while under the influence of drugs or alcohol Keep handles dry clean and free from oil and grease Do not use accessories designed for use without a manual as locking systems Make sure that any attachments are securely assembled before to use the tool Do not remove the labels placed on the tool Before each use ATTENTION Before proceeding with the operation of lub...

Page 6: ... job is complete turn the air compressor off and store as described in the air compressor operator manual ATTENTION With this tool use only accessories reccomanded from the producer Do not use hand accessories because they are not endowed of appropriate locking systems Before assembly the accessories on the tool always check the integrity of their locking systems ATTENTION DO NOT start to work wit...

Page 7: ...aces up Depress the trigger and place one to two drops of air tool oil in the air inlet Connect the tool to an air source cover the exhaust end with a towel and run for a few seconds Every 3 or 4 hours of operation oiling is necessary Do not lubricate tools with flammable or volatile liquids such as kerosene diesel or jet fuel ATTENTION ALWAYS DISCONNECT AIR SUPPLY BEFORE LUBRICATING INSTALLING RE...

Page 8: ...2 EC Machinery Directive EN ISO 12100 2010 EN ISO 11148 9 2012 EN ISO 15744 2008 EN ISO 28927 12 2012 This instrument is warranted to be free from defects in materials and workmanship for a normal use of service for a period of one year Any instrument found detective within one year from the delivery date and returned to the factory with transportation charges prepaid will be repaired adjusted or ...