29
Overload protection:
for
mA°C
terminal inputs only: 500mA/300V Fast fuse
for
10A
terminal inputs only: 10A/300V Fast fuse
Max. Input current:
10A (for inputs > 2A: measurement duration <10 seconds, interval > 15 minutes)
Max. voltage drop:
400 mV
Frequency range:
40 Hz - 400 Hz
Response:
averange (calibrated in rms of sine wave)
[1]
DANGER if the current being measured is > 10A, the display may show the value of the
current but, the measurement is dangerous.
R
R
E
E
S
S
I
I
S
S
T
T
A
A
N
N
C
C
E
E
RANGE
RESOLUTION
ACCURACY
OVERRANGE INDICATION
±(1.0% + 5)
OL shown on the display
1
±(1.0% + 3)
±(2.0% + 5)
Open circuit voltage:
about 0.25V
F
F
R
R
E
E
Q
Q
U
U
E
E
N
N
C
C
Y
Y
RANGE
RESOLUTION
ACCURACY
OVERRANGE INDICATION
10 Hz
0.01 Hz
± (1.0%+3)
OL shown on the display
100 Hz
0.1 Hz
± (0.8%+3)
1 kHz
1 Hz
10 kHz
10 Hz
100 kHz
100 Hz
± (1.0%+3)
200 kHz
1 kHz
[1]
> 200 kHz
Not specified
Input voltage:
1Vrms - 20Vrms
[1]
if the frequency being measured is > 200 kHz, the display may show a reading but, the
measured accuracy is not gearanteed.