5. Present the credential to the reader. Once read by the reader the
Status LED will change from blue to yellow.
6. To enroll additional credentials, repeat 3, 4 and 5.
7. To finish enrolling, move dip switch 12 to the Run position. The
Program/Run LED will change from red to off.
8. To test enrollment of an enrolled credential, present the credential
to the reader. The Status LED and Relay LED will turn green for the
active relay time.
9. Note dip switches 10 and 11, used to select Transmitter button,
are ignored when utilizing a reader connected via the Wiegand
interface.
5.0 Deleting Credentials
1. Move dip switch 12 to the Program position. The Program/Run LED
will change from off to red.
2. Use dip switches 1 through 9 to select the desired enrollment
location of the credential to be deleted.
3. Press the Select Button twice in succession. The Status LED will
change from yellow to blue then red.
4. To delete additional enrolled credentials, repeat 2 and 3.
5. To finish deleting, move dip switch 12 to the Run position. The
Program/Run LED will change from red to off.
6. To test deletion of a previously enrolled credential present the
credential to the reader connected via the Wiegand interface. The
Status LED will change from yellow to red.
6.0 Deleting All Transmitters and Credentials
1. Move dip switch 12 to the Program position. The Program/Run LED
will change from off to red.
2. Set dip switches 1 through 9 to the ‘1’ position (enrollment
location 511).
3. Press the Select Button twice in succession. The Status LED will
change from yellow to blue then red.
4. To finish deleting, move dip switch 12 to the Run position. The
Program/Run LED will change from red to off.
5. To test deletion of a previously enrolled Transmitter press the
Transmitter button that had been selected. The Status LED will
change from yellow to red.
6. To test deletion of a previously enrolled credential present the
credential to the reader. The Status LED will change from yellow
to red.
7.0 Adjusting Relay Activation Time
1. Move dip switch 12 to the Run position. The Program/Run LED will
change from red to off.
2. Adjust dip switches 1 through 4 to select a relay activation time
between approximately 1 and 15 seconds. Timing is adjustable in
approximately one second increments.
3. Press the Select Button once. The Status LED will remain yellow.
4. To test relay activation time with a previously enrolled Transmitter,
press the Transmitter button that had been selected. The Status
LED and Relay LED will turn green for the active relay time.
5. To test relay activation time with a previously enrolled credential,
present the credential to the reader connected via the Wiegand
interface. The Status LED and Relay LED will turn green for the
active relay time.
REFERENCE DOCUMENT
RANGER
®
EDGE RECEIVER CONFIGURATION
© 2022 Farpointe Data, Inc. All rights reserved. Farpointe Data
®
,
Pyramid
Series
Proximity
®
, Delta
®
, Ranger
®
, and CONEKT
®
are the registered U.S.
trademarks of Farpointe Data, Inc. All other trademarks are the property of
their respective owners.
www.farpointedata.com
P/N: 01190-003 ∙ Rev. 1
Farpointe Data, Inc.
2195 Zanker Road
San Jose, CA 95131 USA
Office: +1-408-731-8700
Fax: +1-408-731-8705
[email protected]
Farpointe Data reserves the right to
change specifications without notice.
Feb-25-2022
For installation instructions, please review our
Edge Receiver Quick Start Guide
.
To assist in the tracking of enrolled Transmitters and/or credentials,
please download the
Relay Activation Timing Configurations
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1 second
(default setting)
4
3
2
1
2 seconds
4
3
2
1
3 seconds
4
3
2
1
4 seconds
5 seconds
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
8 seconds
9 seconds
4
3
2
1
10 seconds
6 seconds
7 seconds
4
3
2
1
4
3
2
1
4
3
2
1
11 seconds
12 seconds
4
3
2
1
13 seconds
4
3
2
1
14 seconds
4
3
2
1
15 seconds
4
3
2
1