background image

5.  Present the credential to the reader. Once read by the reader the 

Status LED will change from blue to yellow.

6.  To enroll additional credentials, repeat 3, 4 and 5.
7.  To finish enrolling, move dip switch 12 to the Run position. The 

Program/Run LED will change from red to off.

8.  To test enrollment of an enrolled credential, present the credential 

to the reader. The Status LED and Relay LED will turn green for the 
active relay time.

9.  Note dip switches 10 and 11, used to select Transmitter button, 

are ignored when utilizing a reader connected via the Wiegand 
interface.

5.0 Deleting Credentials

1.  Move dip switch 12 to the Program position. The Program/Run LED 

will change from off to red.

2.  Use dip switches 1 through 9 to select the desired enrollment 

location of the credential to be deleted.

3.  Press the Select Button twice in succession. The Status LED will 

change from yellow to blue then red.

4.  To delete additional enrolled credentials, repeat 2 and 3.
5.  To finish deleting, move dip switch 12 to the Run position. The 

Program/Run LED will change from red to off.

6.  To test deletion of a previously enrolled credential present the 

credential to the reader connected via the Wiegand interface. The 
Status LED will change from yellow to red.

 

6.0 Deleting All Transmitters and Credentials

1.  Move dip switch 12 to the Program position. The Program/Run LED 

will change from off to red.

2.  Set dip switches 1 through 9 to the ‘1’ position (enrollment  

location 511).

3.  Press the Select Button twice in succession. The Status LED will 

change from yellow to blue then red.

4.  To finish deleting, move dip switch 12 to the Run position. The 

Program/Run LED will change from red to off.

5.  To test deletion of a previously enrolled Transmitter press the 

Transmitter button that had been selected. The Status LED will 
change from yellow to red.

6.  To test deletion of a previously enrolled credential present the 

credential to the reader. The Status LED will change from yellow  
to red.

 

7.0 Adjusting Relay Activation Time

1.  Move dip switch 12 to the Run position. The Program/Run LED will 

change from red to off.

2.  Adjust dip switches 1 through 4 to select a relay activation time 

between approximately 1 and 15 seconds. Timing is adjustable in 
approximately one second increments.

3.  Press the Select Button once. The Status LED will remain yellow.

4.  To test relay activation time with a previously enrolled Transmitter, 

press the Transmitter button that had been selected. The Status 
LED and Relay LED will turn green for the active relay time.

5.  To test relay activation time with a previously enrolled credential, 

present the credential to the reader connected via the Wiegand 
interface. The Status LED and Relay LED will turn green for the 
active relay time.

REFERENCE DOCUMENT

RANGER

®

 EDGE RECEIVER CONFIGURATION

© 2022 Farpointe Data, Inc. All rights reserved. Farpointe Data

®

Pyramid 

Series

 Proximity

®

, Delta

®

, Ranger

®

, and CONEKT

®

 are the registered U.S. 

trademarks of Farpointe Data, Inc. All other trademarks are the property of 
their respective owners.

www.farpointedata.com

P/N: 01190-003 ∙ Rev. 1

Farpointe Data, Inc. 

2195 Zanker Road 
San Jose, CA 95131 USA 
Office: +1-408-731-8700 
Fax: +1-408-731-8705 
[email protected]

Farpointe Data reserves the right to 
change specifications without notice.

Feb-25-2022

For installation instructions, please review our  

Edge Receiver Quick Start Guide

.

To assist in the tracking of enrolled Transmitters and/or credentials, 
please download the 

Credential Location Worksheet

.

Relay Activation Timing Configurations

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1 second

(default setting)

4

3

2

1

2 seconds

4

3

2

1

3 seconds

4

3

2

1

4 seconds

5 seconds

4

3

2

1

4

3

2

1

4

3

2

1

4

3

2

1

8 seconds

9 seconds

4

3

2

1

10 seconds

6 seconds

7 seconds

4

3

2

1

4

3

2

1

4

3

2

1

11 seconds

12 seconds

4

3

2

1

13 seconds

4

3

2

1

14 seconds

4

3

2

1

15 seconds

4

3

2

1

Reviews: