8.0 Voltage

12 VDC at the reader is recommended for best operation.

Model

PB-3500

PKB-2600

PKB-3400

Voltage

8 to 14 VDC

5 to 16 VDC

5 to 16 VDC

Current Draw

40 mA typical, 195 mA peak

70 mA typical, 110 mA peak

70 mA typical, 110 mA peak

9.0 fleaPower™ Control Line

To reduce the average current required by the reader, pull the purple conductor low.

10.0 Connection

Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC 
voltage source.

11.0 Troubleshooting

1. When the reader is first powered on it will beep 4-times, and the LED will shine red.
2. Presenting a supported access credential will result in the reader beeping and the LED flashing once.
3.  Mobile operation is optimized for smartphones supporting BLE (Bluetooth LE) version 4.2 or newer. Further, for the downloading of mobile 

access credentials, a stable, high-quality internet connection is recommended.

NOTE: The access panel controls LED functionality, such as switching the LED to green.

If the reader does not recognize the mobile credential or card or tag (no beep, no LED flash) or exhibits short read range, please see the table 
below for possible causes and solutions.

Possible Cause

Corrective Action

Incorrect cabling

Verify gauge, connections and cabling length

Not enough power

12 VDC recommended

Incorrect credential used

Verify if credential technology is supported

Reader/access panel not properly grounded

Earth ground needed—verify shield and reader ground are tied at access panel and connect 
to ground at one point

Supply generating interference

Linear power supply recommended, verify switching power supply before use

Should any of the corrective actions mentioned above not improve performance, disconnect the reader from the access panel and power it with a 
separate power supply or 9VDC battery, and re-test card functionality. By powering the readers separately, most variables that may lead to 
reduced performance can be eliminated. Should the problem persist, please contact Farpointe directly.

QUICK START GUIDE

NORTEK MOBILE-READY PROXIMITY READERS

FCC Compliance Statement: This device complies with part 15 of the FCC rules. 

Operation is subject to the following two conditions: (1) this device may not cause 

harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

Caution: Changes or modifications not expressly approved by Farpointe Data could 

void the user's authority to operate the equipment.

Product can be used without license conditions or restrictions in all European Union 

coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, 

Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, 

Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain, 

Sweden, United Kingdom, as well as other non-EU countries, including Iceland, 

Norway, and Switzerland.

This device contains licence-exempt transmitter(s)/receiver(s) that comply with 

Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). 

Operation is subject to the following two conditions: (1) This device may not cause 

interference. (2) This device must accept any interference, including interference that 

may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est 

conforme aux CNR d’Innovation, Sciences et Développement économique Canada 

applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux 

deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) 

L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 

susceptible d’en compromettre le fonctionnement.

Note: This equipment has been tested and found to comply with the limits for a  

Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful interference when the equipment is 

operated in a commercial environment. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference 

in which case the user will be required to correct the interference at his own expense.

© 2020 Farpointe Data, Inc. All rights reserved. Farpointe Data

®

Pyramid 

Series

 Proximity

®

, Delta

®

, Ranger

®

, and CONEKT

®

 are the registered U.S. 

trademarks of Farpointe Data, Inc. All other trademarks are the property of 
their respective owners.

www.farpointedata.com

Farpointe Data, Inc. 

2195 Zanker Road
San Jose, CA 95131 USA
Office: +1-408-731-8700
Fax: +1-408-731-8705
[email protected]

Farpointe Data reserves the right to 
change specifications without notice.

Access Control Performance Levels:

Destructive 

Attack

Line 

Security

Endurance

Standby 

Power

Level II

Level I

Level IV

Level I