7.0
Grounding
Shield (drain) continuity must run from the reader to the access panel. Shield (drain) and reader ground must be tied
together at the access panel and connect to an earth ground at one point.
8.0
Power and Voltage
Delta multi-technology readers may be powered by the access panel, so the reader is powered on when the access
supply is powered on. However the best case is to power the readers by a separate, linear power supply. Voltage can
range from 5 to 14 VDC, 12 VDC is nominal.
9.0
Reader Wiring
10.0
Connections in Detail
Wire Color
Line
I/O
Description
Red
Reader input voltage
Input
5 to 14 VDC
Green
Wiegand data 0/
Magstripe Clock
Output
Wiegand data or ABA Track II clock
White
Wiegand data 1/
Magstripe Data
Output
Wiegand data or ABA Track II data
Brown
Red LED host control
Input
LED host control. In single line LED control
mode (default mode) pull line low to turn on green
LED. In dual line LED mode pull line low to turn
on Red LED
Orange
Green LED host
control
Input
LED host control, only used in dual LED mode.
In dual LED mode pull line low to turn on green
LED.
Blue
Audio tone host
control
Input Beeper
host
control.
Pull line low for beep.
Purple
Read mode control
Input
Read mode host control. Pull line low for “Sector
Only” mode.
Yellow
Card Present
Output (can be
configured as TTL or
open collector)
Card present line for ABA Track II magnetic
stripe output.
Black
Reader Ground
Input
Reader Ground
Silver
Cable shield
N/A
Cable shield (drain), must be grounded
Wire Color
Function
Green
Blue
Red
Purple
Brown
Shield (Drain)
White
Yellow
Black
Silver
Data 0
Beeper
Reader Power
Read Mode
LED line 1
LED line 2
Data 1
Card Present
Reader Ground
Orange
Figure 1: Wiring Connections to Access Panel
Access
Panel
Reference Documen
t
Delta Multi-
Technology
Reader
s