Possible Cause

Corrective Action

OSDP misconfiguration,  
not configured for OSDP,  
secure channel mismatch

Confirm panel is configured for 
OSDP. Confirm panel and reader are 
both configured for Secure Channel 
(or both unencrypted.) Confirm PD 
address and speed.

Incorrect cabling

Verify gauge, connections and 
cabling length

Not enough power

12 VDC recommended

Incorrect credential used

Verify if credential technology  
is supported

Reader/access panel not 
properly grounded

Earth ground needed—verify shield 
and reader ground are tied at access 
panel and connect to ground at  
one point

Supply generating  
interference

Linear power supply recommended, 
verify switching power supply  
before use

Should any of the corrective actions mentioned above not improve 
performance, disconnect the reader from the access panel and power 
it with a separate power supply or 9VDC battery, and re-test card 
functionality, with an OSDP panel simulator if necessary. By powering 
the readers separately, most variables that may lead to reduced 
performance can be eliminated. OSDP issues often require a packet 
trace, which the installer or panel vendor should be prepared to 
provide if there are problems. Should the problem persist, please 
contact Farpointe directly.

Operating Temperature: 

–31° F to +150° F (–35° C to +66° C)

Operating Humidity: 

0% to 90% Relative Humidity

IP Rating: 

IP67

Many Farpointe Data Readers carry the following certifications:

 

 

FCC Compliance Statement: This device complies with part 15 of the FCC rules. 

Operation is subject to the following two conditions: (1) this device may not cause 

harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

Caution: Changes or modifications not expressly approved by Farpointe Data could 

void the user's authority to operate the equipment.

Product can be used without license conditions or restrictions in all European Union 

countries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, 

Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, 

Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain, 

Sweden, United Kingdom, as well as other non-EU countries, including Iceland, 

Norway, and Switzerland.

This device contains licence-exempt transmitter(s)/receiver(s) that comply with 

Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). 

Operation is subject to the following two conditions: (1) This device may not cause 

interference. (2) This device must accept any interference, including interference that 

may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est 

conforme aux CNR d’Innovation, Sciences et Développement économique Canada 

applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux 

deux conditions suivantes : (1) L’appareil ne doit pas produire de brouillage; (2) 

L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est 

susceptible d’en compromettre le fonctionnement.

Note: This equipment has been tested and found to comply with the limits for a  

Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed 

to provide reasonable protection against harmful interference when the equipment is 

operated in a commercial environment. This equipment generates, uses, and can 

radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference 

in which case the user will be required to correct the interference at his own expense.

For proper PIN security with keypad readers, please review our  

PIN Best Practices Reference Document

.

QUICK START GUIDE

CONEKT

®

 MOBILE-READY CONTACTLESS 

SMARTCARD READERS WITH OSDP SUPPORT

© 2021 Farpointe Data, Inc. All rights reserved. Farpointe Data

®

Pyramid 

Series

 Proximity

®

, Delta

®

, Ranger

®

, and CONEKT

®

 are the registered U.S. 

trademarks of Farpointe Data, Inc. All other trademarks are the property of 
their respective owners.

www.farpointedata.com

P/N: 01402-412 ∙ Rev. 1

Mar-23-2021

Farpointe Data, Inc. 

2195 Zanker Road 
San Jose, CA 95131 USA 
Office: +1-408-731-8700 
Fax: +1-408-731-8705 
[email protected]

Farpointe Data reserves the right to 
change specifications without notice.

Reviews: