ST or st This command will return a string
showing the current settings of the
VP301. Example:
HELP or help
This command will return a
list of commands used for
the VP301Line Multiplier.
?
Help. Does not require entering
the model number.
OSD On/Off
Toggles OSD on and off.
OSD #
Adjusts the vertical position of the
OSD. This command is followed
by an integer between 0 and 120.
Example OSD 55.
VP301 Local / Remote Operation
The unit stores all of its settings in a non-volatile
ram and will return to the last known settings when
the unit is powered up. The only exception is the
Freeze function. The Freeze function will be set off
during the power up cycle.
When a command is received via the RS-232, only
those functions are placed in the remote mode. If a
function is set via the remote, it can be returned
back to local mode by adjusting that function on
the front panel. This is accomplished by creating a
window around that function, when in remote
mode. If that function is turned beyond the window
setpoint, that function is returned to local mode
and becomes active again.
Command String Examples:
Commands can be as simple as:
VP301,B150(CR)
to complex as
VP301,D240,N20,C150,B102,V,T0,A1,F0(CR)
Note (CR) = Carriage Return (OxOd) or ASCII 13
15
APPENDIX A
VP301:B###,C###,K###,T###,N###,D###,V,T1,A1,F0
(Y)
(R)
Freeze
(X)
Digital Filter
Auto-Tint
Input Select
Detail Level
Noise Level
Tint Level
Color Level
Contrast Level
Brightness Level
Header
Summary of Contents for VP301
Page 18: ...17 ...