Faroudja DVP1010 Installation And Operation Manual Download Page 6

INSTALLATION

Unpacking

Remove the DVP1010 unit from the shipping

container and examine it for any signs of shipping

damage or missing items (check inventory list below).

All shipping materials should be saved if the unit is to

be moved or returned for service.  Shipping unit back

to Faroudja for service not in the original box may

result in voiding warranty or additional cost.

Placement 

The processor can be either placed on a table or rack

mounted. A rack mounting installation kit is included.

Securely mount the side rack brackets with the

screws that are provided with the kit.

Ventilation 

The unit uses convection to cool.  A fan is not

needed. As hot air raises out of the top vent, cool air

is drawn in from the bottom and side.  

These vents

must not be blocked

.  When rack mounted, a

minimum of 1.75” (1 rack unit height) of free space is

required above and below the unit to allow for proper

cooling.  A forced air fan should be added to the rack

installation if power amps are located in the same air

space.  Do not install unit above power amps.

Connections 

Because of the high performance of the DVP1010

unit it is very important to use the highest quality

cables possible, for both input and output signals.
To avoid AC ground loop problems, the source

equipment, DVP1010 unit and projector should all be

running on the same grounded AC power line (one

rated for the power requirements).

1.

S-Video input (4-pin DIN) for sources such as

DVDs, Satellite systems,  S-VHS tape decks

(when using S-VHS tapes only), 

Hi-8 tape decks.

2.

Composite video input (BNC) for sources such

as Laserdisc players, cable TV, VHS tape

decks, 8mm tape decks.

3.

YPrPb/RGBs Input (BNC): 480i and HDTV

scan rates are sent to the internal processor

and then output at the selected scan rate. If

the output is set to analog RGBHV or digital

DVI, the unit will automatically transcode the

YPrPb HDTV to RGBHV.

Note on DVDs: 

For proper aspect ratio and to

insure the highest quality image from the DVD

player,  be sure to set the DVD screen shape

to 16:9 in the DVD player's Setup menu. See

the DVD player's owner's manual for details.

4.

High scan rate input (D15F) for sources such

as HDTV signals or computers are passed

through to the projector.  The signal is sent to

the outputs in the same format as the input

unless Transcoding is selected. YPrPb from

HDTV sources can be transcoded to RGBHV,

as well.  Use a BNC to D15 breakout cable if

necessary. The Green, Red, Blue BNCs are

used for YPrPb.

5.

D15F connector output for use with computer

monitors or to a second display device. Use

only short cable runs.  This output can be used

at the same time as the BNC outputs.

6.

DVI Input. The DVI Input will automatically

process 

480i, 

480P,720P and 1080i signals.

Computer rates are passed through to the DVI

output if any of the pass-through inputs are

selected. The DVP1010 will not convert a

computer DVI output to the analog output.

7.

DVI Output: Digital output interface for

compatible displays. All processed analog 

and digital inputs are output to this connector

as well as computer scan rates when the 

pass-through input is selected. Maximum 

cable length is 50ft with a high quality DVI

cable. For longer lengths a distribution system

or fiber optic system must be used.

8.

BNC connectors for main output with RGBHV

or YPrPb signals to display devices. Cable

runs up to 100ft are okay if good quality cables

are used. For YPrPb outputs use:

Red = 

Pr

Green = 

Y

Blue = 

Pb

RGBHV is recommended.

2

INSTALLATION

Inventory

1-DVP1010 Unit

1- Batteries

1-Owner’s Manual

1- Warranty Card

1- Power Cord

1

2

4

5

6

7

8

3

9 10

12

11

13

Summary of Contents for DVP1010

Page 1: ...DVP1010 Digital Video Processor Installation and Operations Manual NTSC PAL Model ...

Page 2: ... align the display device to the processor Be sure to follow all directions for setting up the display found in the display s manual Using a test DVD with the Safe Area test pattern align the image size position and blanking first using the controls found in the display device Only use these controls in the DVP1010 if the display device does not offer these controls or if there is not enough range...

Page 3: ...ings should never be blocked by placing the product on bed sofa rug or similar surface It should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided and the manufacturer s instructions have been adhered to iii SAFETY PRECAUTIONS SAFETY PRECAUTIONS IMPORTANT INFORMATION WARNING TO PREVENT FIRE OR SHOCK HAZARDS DO NOT EXPOSE THIS APPLIANCE TO RAI...

Page 4: ...uct does not operate normally by following the operating instructions Adjust only those controls that are covered by the Operation Manual as an improper adjustment of controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation e If the product has been dropped or damaged in any way f When the product exhibits a distinct c...

Page 5: ...ay be copied photocopied translated or reproduced to any electronic medium or machine readable form without prior consent in writing from Faroudja The Faroudja name logo and Picture Plus are registered trademarks of Faroudja Specifications subject to change without notice All Rights Reserved The Faroudja DVP1010 is covered by the following United States patents 4 030 121 4 179 705 4 240 105 4 262 ...

Page 6: ...to the internal processor and then output at the selected scan rate If the output is set to analog RGBHV or digital DVI the unit will automatically transcode the YPrPb HDTV to RGBHV Note on DVDs For proper aspect ratio and to insure the highest quality image from the DVD player be sure to set the DVD screen shape to 16 9 in the DVD player s Setup menu See the DVD player s owner s manual for detail...

Page 7: ...gnals to the selected output of the processor Any HDTV signal connected to the YPrPb BNC or DVI inputs will be cross converted Any HDTV or PC signal connected to the D15 input will be passed through without processing PC signals via the DVI input will be sent to the pass through To pass through HDTV signals to avoid processing select the passthrough input DVI is passed through to the DVI output an...

Page 8: ...Function Up or Down to select the available Functions Press the Value Up or Down keys to change values or to select options SETUP MENU FUNCTIONS Set NTSC SCAN RATE Select the required scanrate by using the right and left arrows When the desired rate is displayed on the LCD display press the STORE key The DVP1010 will ask you Are you sure and press the STORE key again The scanrate is now selected S...

Page 9: ...isabling this unused input will remove it from the input menu list Set Passthru Transcode Disable Default Enable Note YPrPb HDTV signals via the D15 input or the YPrPb BNC inputs can be transcoded to RGB when this feature is enabled Set Component Input Standard DVD Default Professional Betacam Note Only use professional setting when using a device that conforms to SMTPE Betacam levels Set RGB Inpu...

Page 10: ... next menu page A list of available Functions will appear Press Function Up Down keys to select an adjustment Use Value Left Right keys to adjust The main menu drops away and a single line menu appears Use the Function keys to return to the drop down menu Press Menu at any time to cancel OSD Note Unused inputs can be deactivated for simpler operation of the processor See the Setup instructions for...

Page 11: ...on a Wide Angle screen there are black bars on the left and right of the image The sidebars can be changed to gray using the Blanking Level control located in the Display menu If filling the entire screen is desired select Letterbox The image will fill the screen but the top and bottom 1 3 of the image will be cut off overscanned When watching 2 35 aspect ratio movies on a 16 9 1 77 screen it is n...

Page 12: ...or System Normal default Bypass For some DVDs with computer animation or with very high levels of color the Faroudja patented chroma edge processing circuits may not be needed and can be turned off Bypass For most sources the Normal setting should be selected These settings can be stored as a Profile Note Any changes to the picture level adjustments are automatically stored after one minute has pa...

Page 13: ... The test pattern generator in the DVP1010 is set to SMPTE standards To insure proper output levels for display setup the picture controls in the DVP1010 cannot be accessed when the test patterns are being used Adjust levels if needed in the display device INPUT PICTURE DISPLAY PATTERNS TEST PATTERNS ON SELECT CONVERGENCE AVAILABLE PATTERNS 10 step Gray Scale Check gray scale Cb Ramp Check lineari...

Page 14: ... 128 default Color OFF Power OFF ON Power ON P 0 8 1 8 User 0 Factory Recall Profiles PM 0 1 0 Normal1 Bypass Advanced Color System PY PassThru Transcoded Input R RGB input ST Report Current Status T 0 255 128 default Tint TP 0 Off 1 100 Color Bars 2 Reverse Color Bars 3 10 step Grayscale 4 Luma Ramp 5 Cb Ramp 6 Cr Ramp 7 Green 8 Red 9 Blue 10 Convergence 11 Active Boarder 12 Multiburst 13 100 Win...

Page 15: ...nu SRPHELP PAL Scan Rate Help Menu TB 000 192 Top Blanking VD Video Input Disabled STHELP Setup Help Menu VE Video Input Enabled W 0 4 3 1 Widescreen 2 Wide 4 3 Screen Shape XD YCrCb Input Disabled XE YCrCb Input Enabled YD S Video Input Disabled YE S Video Input Enabled NTSC SCAN RATE LIST USE ONLY BY QUALIFIED TECHNICIAN SRN2 1920 x 540 SRN3 800 x 600 SRN4 1280 x 720 SRN5 1024 x 768 SRN6 1280 x ...

Page 16: ...tput Horizontal Vertical Scan Rate Frequency Frequency 1920 x 540P 33 8 Khz 59 94 Hz 720 x 576P 31 3 Khz 50 00 Hz 720 x 576P 62 5 Khz 100 00 Hz 800 x 600P 37 6 Khz 59 94 Hz 1280 x 720P 45 0 Khz 59 94 Hz 1280 x 720P 37 5 Khz 50 00 Hz 1024 x 768P 60 5 Khz 75 00 Hz 1024 x 768P 80 6 Khz 100 00 Hz 1024 x 768P 48 3 Khz 59 94 Hz 1366 x 768P 48 3 Khz 59 94 Hz 1440 x 960P 62 9 Khz 59 94 Hz 1280 x 1024P 63 ...

Page 17: ... 960 37 10 1280 x 1024 34 20 1365 x 1024 49 19 1400 x 1050 49 19 1920 x 1080 39 4 PAL Horizontal Vertical Scan Rate Default Default 720 x 576 50 39 17 720 x 576 100 44 17 1280 x 720 50 25 15 1024 x 768 75 39 18 1024 x 768 100 37 18 1920 x 1080 50 40 18 HORIZONTAL AND VERTICAL POSITION The horizontal and Vertical default position is optimized for each scan rate Below is the chart of the default num...

Page 18: ...e IR sensor input 5V to 12V 3 5mm Tip Outputs Progressive R G B BNC or DB15 RGB 700mVpk pk 75Ω H Cs V Sync 4V 2KΩ YPrPb 700mvpp Sync on Y 1Vpk pk RGsB Gs 1Vpk pk RGB 700mVpk pk D15F Pin Function Fuse Type LT4Al250V Safety Standards UL CUL TUV J60950 EMC Standards FCC Part 15 Class B CISPR 22 Class B EN61000 3 2 EN61000 3 3 EN55022 Class B Digital Video Interface DVI Female Screen Trigger 12V 3 5mm...

Page 19: ...epaid Warranty may be void if unit is not returned to Faroudja Service in the original shipping carton Should a product fail to conform to the warranty above then Faroudja shall at Faroudja s sole option i repair the non conforming product or portion thereof provided that the product is returned to Faroudja within the warranty period in accordance with the return procedures set forth above or ii p...

Reviews: