background image

V1.0 

www.farmscanag .com                              AM-JACKAL-C-QG 

 

Page 1 

Quick Start Guide 

 Jackal Spray Control 

Setup 

 Auto Mode 

 

 

 

 

 

Press 

SETUP

 

Highlight 

WIZARD

 & press 

SELECT

 

Highlight 

Sprayer

 & 

Press 

NEXT

 

Select Spray 

AUTO 

 

 

 

 

Press 

NEXT

 to setup your 

Flow Meter 

NB: Please have your Pulse 

Per Litre (PPL) factor from 

your flow meter to hand. 

For Hardi ½ inch 

 120ppl 

For Hardi ¾ inch 

 50ppl 

Press the 

DOWN 

arrow to 

Manual Ratio 500.00 & 

Press 

EDIT 

Refer to page 28 of the 

manual to use the Auto Set 

function

 

Using the NAV buttons enter 

the PPL factor as displayed on 

the flow meter tag. 

Press EXIT when done. 

NB the placement of the 

decimal point 

Press NEXT to accept the 

new manual ratio (PPL)

 

 

 

 

 

Press NEXT to accept the 

L/Ha

 

Press NEXT  

(Don’t worry about editing 

the alarm values)

 

Press NEXT 

(Don’t worry about editing the 

Name for the front screen)

 

Select 

Wheel or GPS 

 

Setup Guides for each of 

these can be found on 

Pages 22 to 24

 

 

 

 

 

 

Press 

EDIT

 and change the 

number of sections required 

to control. 

Press 

NEXT

 

Using the 

NAV

 & 

EDIT 

keys, 

highlight and edit the 

section width values as 

required. Press 

NEXT

 

 

 

Summary of Contents for Jackal

Page 1: ...the manual to use the Auto Set function Using the NAV buttons enter the PPL factor as displayed on the flow meter tag Press EXIT when done NB the placement of the decimal point Press NEXT to accept the new manual ratio PPL Press NEXT to accept the L Ha Press NEXT Don t worry about editing the alarm values Press NEXT Don t worry about editing the Name for the front screen Select Wheel or GPS Setup ...

Page 2: ...OTE Slow Hold is an optional function that can be set to operate at a minimum speed equivalent to the minimum recommended pressure for a given target rate speed based STOP Will simply put the Jackal on hold at a set speed Press NEXT Press NEXT Don t worry about editing the Name for the front screen Press SKIP Don t worry about setting up a tank level sensor Press NEXT to finalise the Wizard and re...

Page 3: ...e a higher lower rate If the desired rate cannot be achieved it s possible the Flow Control Valve is working in the reverse direction PLEASE TURN OVER FOR COMMON QUESTIONS ANSWERS Common Questions Answers QUESTION ANSWER I think my control valve is working back to front My rates seem to only adjust in one direction Setup Outputs 1 Rate Select Press the Right arrow to change the value to Rate Exit ...

Page 4: ...f you require a permanent solution press Setup Front Screen 1 Rate L Ha Edit Press the left arrow once and change the MODE Rate to MODE RateManual Exit when done Press the PAGE button to Rate Rate Flush Use the Rate or Rate to manually adjust the flow control valve How do I check I am getting a GPS input Setup GPS Serial Select Confirm in this window or Press Setup confirm the NMEA messages are re...