PROPER CONNECTION TO THE TRACTOR
For proper connection, the following facts must be observed:
Outlet hose
-
Do not connect the free drain hose to the tractor distributor! (pressure in the reverse branch would thus
be increased)
-
Large quick coupling on the free drain must not be changed for the smaller diameter.
-
Oil returning through the outlet pipe must not be throttled anywhere
-
Maximum allowed pressure value in the free drain hose is 5 bar, higher pressure pushes the shaft seal
out, which causes damage to the hydraulic motor fan
Pressure hose
-
Connect the pressure hose to the circuit giving priority to the oil supply
Picture. 6 – Position of quick couplings in the tractor
6.6.1
Connecting the free drain
hose
Connect the outlet hose (outer
⌀
27 mm) with the large quick coupling to the free drain to the tractor tank.
In case that there is no free drain to the tank attached to the tractor as standard, please contact the tractor
manufacturer (dealer) for information regarding the possibilities of a free drain end piece.
Picture 7 – Outlet hose connection
Free drain to the
tractor tank must
be all time
connected, even if
fan is not working
Free drain to the tank
Tractor
distributor
Summary of Contents for FALCON 3
Page 6: ...Manual FALCON 3 4 6 8 6 99 ...
Page 20: ...Manual FALCON 3 4 6 8 20 99 6 3 HYDRAULIC DIAGRAM OF THE MACHINE ...
Page 77: ...Manual FALCON 3 4 6 8 77 99 ISO alarms ...
Page 78: ...Manual FALCON 3 4 6 8 78 99 Hydraulic alarms Regulation alarms ...
Page 79: ...Manual FALCON 3 4 6 8 79 99 ...
Page 80: ...Manual FALCON 3 4 6 8 80 99 Machine specific alarms ...
Page 81: ...Manual FALCON 3 4 6 8 81 99 ...
Page 82: ...Manual FALCON 3 4 6 8 82 99 ...
Page 83: ...Manual FALCON 3 4 6 8 83 99 ...