MAINTENANCE AND STORAGE
Daily maintenance:
The following maintenance should be done after daily job.
1. Cleaning the oil and dust on the surface of the machine.
2. Clean the chemical tank with clean water and wipe it dry.
3. Check if there is any leakage of water or fuel. If there is a leakage, remedy
procedures are to be taken.
4. Check to see if the screws are loose or lost. If so, please tighten the screw or
replace.
5. The battery must be charged before storage. Charge before every use in case
of power shortage.
6. The machine after maintenance should be stored in a place which is dry and
has good ventilation. It must be far away from any fire source and sunlight.
Long term Storage:
The machine which is to be stored t for a long time should be maintained as follows:
1. Clean the machine surface carefully.
2. Discard any medicine in the tank and the pump, clean them with clean water.
3. The battery must be charged before storage. If stored for a long time, it should
be charged every two months.
4. All the plastic parts must neither be exposed to the sunlight nor pressed by
heavy matter.
5. Cover the machine with plastic dustcoat and store in a dry and clean place.
a) Cleaning
1. Clean chemical container
Discard remaining chemical liquid and wash it thoroughly. Fill one litre of
water into the chemical tank and then rinse it slightly.
2. Clean the inside liquid pump
After cleaning the chemical tank, fill with clean water again and start liquid
pump to mist so as to clean the whole pipeline.
3. Clean the filter net
a) Clean the filter net in the mouth of the chemical tank.
b) Clean the filter net of suction inside the chemical tank.
There is a filter net of suction at the bottom of the chemical tank to avoid the
dust coming from the filter net of the mouth of the chemical tank to be sucked
into the liquid pump. The filter of the suction is jammed to spray abnormally
and will infect the liquid pump greatly. So please take out the filter of suction
to clean carefully after operating. Fix it carefully after cleaning.
Don’t allow the remaining chemical liquids and the water used for
washing the machine flow into rivers, lakes, ponds or cloacae in
order avoid pollution.Please deal with it innoxiously