![Farm King 1460 Operator And Parts Manual Download Page 60](http://html.mh-extra.com/html/farm-king/1460/1460_operator-and-parts-manual_545188060.webp)
Operation - Fertilizer Applicator 1460
60
Spray System Test - Ace Centrifugal Pump (Option)
Dry Test
Figure 41
Enter the operator’s position and turn the tractor ignition
switch to the “ON” position (Do Not start engine.)
Turn the spray controller “ON”.
Press wing section switches on the controller, one at a
time and operate each of the manifold valves (Item 1)
.
Verify that each manifold valve fully opens and closes.
Also verify that the correct switch on the controller is
operating the correct section manifold valve.
Wet Test
Add approximately 300 gallons of clean water to the
product tank. (See “Filling The Product Tank” on
page 57.)
Inspect the system for leaks. Repair as needed before
operating fertilizer applicator.
Verify that there is liquid in the pump vent line.
NOTE: Maximum hydraulic flow for the pump is 11
gpm. Start with 5 gpm hydraulic flow and
increase / decrease as needed.
Enter the operator’s position, start the engine.
Engage the tractor hydraulics. (See the tractor’s
operator’s manual for the correct procedure.)
Turn the spray controller “ON”.
Place the spray controller in “TEST” mode.
Turn all wing section switches “ON”.
Verify that the pump is flooded and vent line is filled with
fluid.
Engage product pump hydraulic circuit (White markers)
and place into “detent” position. (See the tractor’s
operator’s manual for the correct procedure.)
Operate the product pump for one minute to flush debris
from supply lines (If required). Turn off the pump by
moving the hydraulic control to the “float” position.
Determine targeted GPM flow rate.
Select and install properly sized orifices / tips. Perform a
“nozzle output check test” to verify application rate.
Inspect spray system components for leaks, loose fittings
and possible pinch points. Tighten loose fittings.
Drain system and clean the line strainer screen.
NOTE: Cover spray monitors daily to prevent
damage to components.
Review the spray controller operator’s manual and
be familiar with spray controller calibration and
operation before starting.
B-11022
1
The pump must be filled with liquid during operation
to cool the seals. Without liquid to cool the seals,
pump failure will occur immediately.
Summary of Contents for 1460
Page 2: ......
Page 4: ...Table of Contents Fertilizer Applicator 1460 4 ...
Page 6: ...Warranty Registration Fertilizer Applicator 1460 6 ...
Page 8: ...Introduction Fertilizer Applicator 1460 8 ...
Page 12: ...Introduction Fertilizer Applicator 1460 12 ...
Page 14: ...Safety Fertilizer Applicator 1460 14 ...
Page 26: ...Safety Fertilizer Applicator 1460 26 ...
Page 28: ...Assembly Fertilizer Applicator 1460 28 ...
Page 40: ...Assembly Fertilizer Applicator 1460 40 ...
Page 42: ...Operation Fertilizer Applicator 1460 42 ...
Page 66: ...Maintenance Fertilizer Applicator 1460 66 ...
Page 80: ...Maintenance Fertilizer Applicator 1460 80 ...
Page 144: ...Parts Identification Fertilizer Applicator 1460 144 ...
Page 146: ...Specifications Fertilizer Applicator 1460 146 ...
Page 150: ...Specifications Fertilizer Applicator 1460 150 ELECTRICAL SCHEMATIC ELECTRICAL SCHEMATIC ...
Page 160: ...Specifications Fertilizer Applicator 1460 160 ...
Page 161: ...Warranty Fertilizer Applicator 1460 161 WARRANTY WARRANTY 163 ...
Page 162: ...Warranty Fertilizer Applicator 1460 162 ...
Page 167: ......