FARFISA INTERCOMS PDX 2000 Manual Download Page 9

Mi 2453 

Gb - 9 -

Operating functions

The switchboard can operate in the following operating mode: 
OFF, ON and Direct Call.

Switchboard OFF (night)

Switchboard is not operative while the other devices of the 

system still continue to work as intended. All the call directed 
to the switchboard will be lost.

Switchboard ON (day)

All the call either originated by the door stations or by internal 

users are intercepted by the switchboard except those made 

by the secondary door stations which can be managed by a 

secondary switchboard (if present in the installation).

Direct Call

Enabling this function all the call originated by the door 

stations are diverted directly to the internal users without being 

intercepted by the switchboard. Switchboard will handle only 

the 

call from internal user

s and is able to 

manage bookings

 

and 

make an inclusions

 to a communication in progress.

Operating instructions

Power-OFF

Keep pressed the 

 button until the switchboard switches 

OFF or when the “device manager” menu appears select 

power “OFF” and then press 

. Already stored bookings 

will not be lost.

Power-ON

Keep pressed the button 

 for some seconds, the switch-

board powers ON and starts to operate according to the 

previous settings.

 Device manager

When the switchboard is ON, pressing shortly the button 

 to display the “Device Manager” menu; in the menu are 

listed the following functions: Power-OFF, keypad lock, ringer 

tones OFF, ringer tones ON and software release.

Keypad lock

Activating this function, the keypad of the switchboard is 

locked, it is only possible answer to the incoming calls from 

door stations or internal users. In “Device Manager” menu 

select “keypad lock” and press 

; on the display will 

appear  . To unlock the keypad press for several seconds 

the button 

Ringer tones OFF and ON

To set OFF (or ON) all the ringer tones of the switchboard it is 

necessary: - access the menu “Device Manager” by pressing 
shortly the button 

 - select “Silent” - press 

; LED 

 

will light-ON. To activate again the ringer tones select “Ringer 
ON” and press 

; LED 

 switches-OFF.

Release Software

To display the software release of the switchboard select 

“release” and press 

. To exit this page press 

.   

  Operating Modes

Enable Direct Call

To enable the Direct Call function it is necessary: press 

 

- select “Mode” - press 

 - select “Direct dialling” - press 

; LED 

 will light-ON showing that the Direct Call 

function has been activated

Note:

 in case of power failure or switching-OFF the 

switchboard, the function 

Direct Call 

remains stored and 

will be activated again at the next power-ON.

Back to the operating mode “DAY”

To disable the Direct Call function and operate in “DAY” mode 
it is necessary: - press 

 - select “Mode” – press 

 

- select “Normal” - press 

; LED 

 switches-OFF.

- OFF

Keypad lock

Silent

Device Manager

A

J

T

G

P

W

D

M

B

K

U

H

Q

X

E

N

C

L

V

I

R

Y

S

Z

F

O

1

4

7

2

5

8

0

3

6

9

OFF

Silent

- Keypad lock

Device Manager

21.09.11

11.06

Linea libera

A

J

T

G

P

W

D

M

B

K

U

H

Q

X

E

N

C

L

V

I

R

Y

S

Z

F

O

1

4

7

2

5

8

0

3

6

9

21.09.11

11.06

Linea libera

OFF

-

Silent

Keypad lock

Device Manager

Keypad lock

Silent

- Ringer ON

Device Manager

Back

Normal

- Direct dialling

Mode

Door Stations

Booking

-

Mode

Menu

Back

Direct dialling

- Normal

Mode

Door Stations

Booking

-

Mode

Menu

Summary of Contents for PDX 2000

Page 1: ...Mi 2453 SWITCHBOARD A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 PDX 2000 Mi 2453 for DUO System ...

Page 2: ...st be exclusively operated for its intended use The manufacturer cannot be held responsible for possible damage caused by improper erroneous and unreasonable use Keep packing parts away from children i e plastic bags expanded polystyrene etc Do not open the device when it is ON The installation must be made by specialized personnel in compliance with the regulations in force Alwaysrefertospecializ...

Page 3: ...ll the functions to set and program the switchboard To move inside the submenus use the arrow buttons 7 Arrow up or back Main functions Three operating modes day night and direct call Communication between internal users or internal users and door stations Monitor of one or more door stations Inclusion on a busy user Booking of calls it can store up to 50 unanswered calls Selective door lock relea...

Page 4: ...de of the switchboard has been activated Shows an opened door if this function has been foreseen in the installation Shows that the diverted to a user operating mode of the switchboard has been activated if supported by the software version Shows the activation of the internal relay in monostable or bistable operating modes Handset on hook Handset off hook Call to or from a user Communicationinpro...

Page 5: ...witchboard must be programmed with the same address of switchboard according to the previous example 201 for programming please follow the proce dure indicated in the technical manual which comes with the product Program all the door stations to set them for the pres ence of the switchboard Terminal board LI LI Duo line input LO LO Duo line output A A Auxiliary power input 12 15Vdc 0 5A C Common c...

Page 6: ...wisted cable CAT5 cable 2x1mm AWG17 2x0 32mm AWG22 2x0 2mm AWG24 A D 50 m 164 ft 10 m 33 ft 5 m 17 ft B 150 m 492 ft 150 m 492 ft 150 m 492 ft C 150 m 492 ft 150 m 492 ft 150 m 492 ft E 30 m 98 ft 20 m 65 ft 20 m 65 ft F 150 m 492 ft 50 m 164 ft 35 m 115 ft PA SE PRS210 VD2120 TD2100PL CD213 PL LP LP 2220 230V 230V 127V 127V 0 0 S1 S2 Connection of a local calling button bell function Connecting a...

Page 7: ...1 1 2 3 4 5 LM LM LO LO LI LI 2221S LP LP PRI 110V 240VAC 2221ML J1 230V 127V 0 LP LP LO LO LI LI PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 INTERCOM VIDEOINTERCOM MULTI WAY SYSTEM WITH 1 MAIN DOOR STATION AND A SWITCHBOARD 1 2 termination 47Ω 3 4 termination 70Ω 4 5 termination 100Ω 2 3 open line default 2 3 open line default FP Floor call push button optional...

Page 8: ...oor station 1 B is equal to the sum of distances B1 B2 and B3 B1 B2 B3 B secondary line a secondary line b L2 L2 230V 127V 0 2273 2273 2221ML SW2 SW2 4 3 2 1 ON 4 3 2 1 ON ON OFF LP LP L1 L1 E DV2420 DV2422A J1 1 2 3 4 5 J1 1 2 3 4 5 LM LM LP LP LD LD PDX2000 A J T G P W D M B K U H Q X E N C L V I R Y S Z F O 1 4 7 2 5 8 0 3 6 9 230V 127V 0 PRS210 LI LI LI LI L1 L1 B LI LI LO LO L2 L2 L1 L1 LP LP...

Page 9: ...witchboard is locked it is only possible answer to the incoming calls from door stations or internal users In Device Manager menu select keypad lock and press on the display will appear To unlock the keypad press for several seconds the button Ringer tones OFF and ON To set OFF or ON all the ringer tones of the switchboard it is necessary access the menu Device Manager by pressing shortly the butt...

Page 10: ...station it is necessary to close all the communications in progress Connection of the switchboard to the door sta tions At any moment it is possible to monitor the door stations pressing the button If in the installation there are more door stations pressing the button the switchboard will be connected with the last door station which has made a call For a selective connection with a specific door...

Page 11: ...his feature can not be guaranteed for all the users To interrupt a communication between to users see chapter Inclusion External to Internal Communication While the switchboard is in communication with a door sta tion it is possible to transfer the call to an internal user for 60 seconds which can be extended following the below procedure press the button door station actually in commu nication wi...

Page 12: ...correct address press cursor moves to a small box on which there is written the number 0 do not change it only in some specific cases it is possible to change this number press select Save press changing is automatically stored and you will be back to the directory list Delete a user In the directory select the user to be deleted press select delete press with the button select Yes press user is a...

Page 13: ...erating Mode You access the operating modes of switchboard day or direct calling See enable direct call and back to the operating mode day Settings In this menu it is displayed the list of settings Time Date Language Ringing Tones Ringing Volume Backlighting LCD Contrast and Advanced Settings Time Select Time and press with the keypad enter the actual hour press with the keypad enter the actual mi...

Page 14: ...C NC NO can be used for additional ringer for the incoming calls a lamp signaller can also be driven power ON a CCTV monitor only during the calls from the door stations bistable relay operated by the button when the relay is activated the LED will light Up monostable relay operated by the button when the relay is activated the LED will light Up timing of relay should be set according the instruct...

Page 15: ...witchboards at the same hierarchical level it is necessary to set one of them as Mas ter and the others as Slaves for secondary switchboards this setting is required only for those connected to the same secondary line more switchboards connected to a different secondary lines doesn t require to be set as Master and Slave on the contrary all of them must be set as Mas ter From the factory all the s...

Page 16: ...7 Osimo AN Italy Tel 39 071 7202038 r a Fax 39 071 7202037 e mail info acifarfisa it www acifarfisa it Cod 52704880 Mi 2453 Smaltire il dispositivo secondo quanto prescritto dalle norme per la tutela dell ambiente Dispose of the device in accordance with environmental regulations Écouler le dispositif selon tout ce qu a été prescrit par les règles pour la tutelle du milieu Eliminar el aparato segú...

Reviews: