again keep pressed the button “

” for more

than 4 sec.; yellow LED starts quickly flashing;
enter the 3 digit of the 

1st user secondary

address 

(codes from 1 to 200) following the

procedure reported on the paragraph “

Entering

codes or addresses

”;

press  the  button 

  to  confirm  the  present

address and move to the 2nd user address; an
acknowledge tone will be heard;
enter the 3 digit of the 

2nd secondary user

address 

and confirm by pressing button 

;

proceed entering the 3rd and 4th secondary
user addresses consumer (if necessary) or to
press twice the “

” to pass to the insertion of

the common internal address;
enter the 3 digit that compose the 

common

internal address 

to the 4 new user addresses

(codes from 000 to 007) following the procedure
of  the  paragraph  “

Entering  codes  or

addresses

”.

Note: the internal common address has to be
unique and different from you address him in-
side  eventually  programmed  on  other
videointercoms and/or intercoms that has the
same user address;
to press “

” to confirm and to return of choice

of programming; an acknowledge tone will be
heard and the yellow LED lights-ON continu-
ously;
pick up the handset for exit the programming
mode.

Note: If you want to make intercom calls, you must
program the call buttons with the codes of the
users you want to call.

Example

How to program three videointercoms with user
addresses 101, 102 and 103; from which user
103 should receive also calls addressed to user
101 and 102; user 101 and 102 should receive
only calls addressed to them.
- User 101 must be programmed only with user

address 101 and internal address 000.

- User 102 must be programmed only with user

address 102 and internal address 000.

- User 103 must be programmed with user ad-

dress 103, internal address 000, 1

st

 secondary

address 101, 2

nd

 secondary address 102, inter-

nal common address 001 being the internal ad-
dress of videointercoms 101 and 102 already
programmed to 000.

Note:  store  only  the  addresses  of  the
external door stations to which the user
can  be  connected.  Don’t  store  the  ad-
dresses of external door stations belong-
ing to different buildings even if in the
same installation.

Buttons 1,2,3,4 and 5.

These buttons can be used to:

  

make intercommunicating calls;

- to call users of different apartments it is

necessary to store in each button of your
monitor the address of the user you wish to
call pressing that button (codes from 

001

to 

200

).

- to call other videointercoms installed in the

same apartment (local intercommunicating
service),  it  is  necessary  to  store  in  the
buttons 1, 2, 3, 4, 5  of each monitor always
the code 

000

; starting from button 1 and

going on until you have programmed, with
the code 000, as many buttons as are the
videointercoms installed in the apartment
(max 6 units) you wish to call; automatically
by pressing buttons 1,2,3,4,5 of one unit
you will call the unit whose internal address
is related to the pressed button according
to table 3. For example if you press the
button 3 from the videointercom whose
intercommunicating address is 

002 

you

will call the user with intercommunicating
address 

003.

monitoring external door stations 

(it is

suggested to use button   to monitor the
1

st

  external  door  station)  to  enable  this

feature store the address of the external
door station (codes from 

231 

to 

250

).

optional functions operated by means
of the actuators art

.

2281

; to enable this

functions store the address of the actuator
to be operated (codes from 

211 

to 

220

).

To make the programming it is necessary:

enter the programming mode 

following

the  instructions  described  in  “

Enter  the

programming  mode”;

a

 - keep pressed for more than 4 seconds

the button you wish to program; yellow
LED starts flashing;

b

 -enter the 3 digit of the code or address

you wish to store following the procedure
reported  on  the  paragraph  “

Entering

codes or addresses

”;

c

 -press the button 

; an acknowledge

tone  will  be  heard  and  the  yellow  LED
lights-ON continuously;
repeat  phases 

a-b-c

  to  program  other

buttons or exit the programming mode by
hanging up the handset; yellow LED turns-
OFF.

Notes

.

- In each button can be stored only one code

or address.

- Intercom conversations or connections with

users and external stations of other buildings will
not be possible if digital exchanger art.2273 is
installed.

Programming the number of ringing call

The videointercom can receive 4 different calls that
can  be  changed  as  indicated  in  the  procedure
below. The default programming values and the call
sequence are shown in table 1.
All programming operations must be carried out
with the handset in idle position.

Keep pressed the button "

" for more than 4

seconds; the yellow LED turns ON and you hear
the ring tone that was programmed for calls from
external door station.

a

 - press the button “ ” repeatedly to select the

ring tone.

b

 - press the button “

” to confirm and go on to

select the number of rings.

c

 - press the button “ ” as many times as the

desired number of rings (once = 1 ring; 4 times =
4 rings).

d

 - press the button “

” to confirm and go on to

program the ring tone for intercom calls.
If you want to change the other two tone rings (call
from other user or floor call), you must repeat
steps 

a-b-c-d

.

Pick up and close the handset for exit the pro-
gramming mode; yellow LED turns-OFF.

Adjusting the volume

With the handset in idle position, you can adjust 4
volume levels for all ring tones, as indicated below:

press the button “

” for 4 seconds; the yellow

LED turns ON and you hear the external door
station ring tone;
hold the button “

” pressed and release it when

you hear the desired volume;
pick up and close the handset for exit the pro-
gramming mode; yellow LED turns-OFF.

The volume levels are stored and will be used for the
next calls.

More  programming  operations  for
specific  functions

How to program secondary user addresses

(

additional programming operation that does not

depend on the programming operations of user
and internal station addresses)
The following programming operation allows you to
save  4  additional  user  addresses  on  the  same
videointercom  (i.e.:  exchanger  function,  video-
intercom installed in common area with multiple
users, etc.).

N.B.:

  videointercom  must  be  programmed  also

with the internal common address as specified in
the following.

To make the programming it is necessary:

enter  the  programming  mode 

following  the

instructions described in “

Enter the programming

mode”;
keep pressed the button “

” for more than 4

seconds; yellow LED starts flashing;

To make the programming easier and to remind your self the stored codes, please fill in the following table

Summary of Contents for EX3262

Page 1: ...0 50 C Maximum admissible humidity 90 RH Donn es techniques Alimentation directe depuis la ligne Absorption repos 8mA pendantlefonctionnement 0 5A EX3262 0 4A EX3262C cran EX3262 4 CRT plat n b EX3262...

Page 2: ...button to confirm an acknowl edge tone will be heard and the yellow LED lights ONcontinuously proceed with another programming phase or exittheprogrammingmodebyhangingupthe handset Note If one of the...

Page 3: ...ations it is suggested to use button to monitor the 1st external door station to enable this feature store the address of the external door station codes from 231 to 250 optional functions operated by...

Page 4: ...es Toresetthevideointercomdefaultprogramming values and delete all the variations made in the programmingmodeyoumust enter the programming mode following the instructions described in Enter the progra...

Page 5: ...tton is programmed correctly youcanmonitortheexternalstations max 4 in sequence by pressing the same button again and again ThevideointercomwillbeturnedONforabout 30seconds Themonitoringwillbeinterrup...

Page 6: ...ode n est affect aux boutons nombrederetentissementsettypedeson nerie voir tableau 1 Attention uniquement la programmation de l adresse de l usager est obligatoire toutes lesautressontfacultatives Ent...

Page 7: ...sieursfoissurlebouton poussoir pour s lectionner la sonnerie d sir e b appuyer sur le bouton poussoir pour confirmer et passer au choix du nombre de retentissements c appuyerautantdefoissurlebouton po...

Page 8: ...tiv d sactiv mode 6 les bornes GC GE s activent lors d un appel intercommunicant 3 d sactiv activ d sactiv mode 7 r serv laisser d sactiv d sactiv d sactiv 1 Depuis le poste interne branch au bouton p...

Page 9: ...voirunappeldepuisun autreusager Avecl installation repos onpeutappelerun autreusager Pourproc der cetteop ration il faut avoir pr alablement m moris sous le bouton poussoir l adresse de l usager que l...

Page 10: ...ALIANO E NGLISH F RAN AIS E SPA OL P ORTUGU S D EUTSCH 14 Esempio di programmazione manuale di un videocitofono Example of manual programming of a videointercom Exemple de programmation manuelle d un...

Page 11: ...Intercoms Via E Vanoni 3 60027 Osimo AN Italy Tel 39 071 7202038 r a Fax 39 071 7202037 e mail info acifarfisa it www acifarfisa it Cod 52704290 Smaltire il dispositivo secondo quanto prescritto dalle...

Reviews: