FARD lighting STAR N04 User Manual Download Page 2

User Guide

STAR N04

2

Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which 
damages all connected products. This will cause voltage drop and also dimmed lighting output.

CAUTION

Keep extension lead 
wires as short as possible.
Refer to below table for 
specific length.

CONNECTION GUIDE

80 mm

200 mm

400 mm

316 mm

Use 10% to 20% shorter length
than usual for circular arrange

Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit 
cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.

LAYOUT DENSITY 

GUIDELINES

RECOMMENDED PITCH PER DEPTH

120 mm

120 mm

200 mm

150 mm

100 mm

100 mm

70 mm

80 mm

RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH

CONNECTION WITH 

POWER SUPPLY

Output (W)

Model Name

Max Q’TY -  Colors*

Recommended

Extension Wire

Output (A)

Max Q’TY - White*

Maximum Length

30W

2.5A

PSCS-0030-12

5M (15FT)

VCTF1.25

AWG18

60W

5A

PSCS-0060-12

5M (15FT)

VCTF2.0

AWG14

120W

10A

PSCS-0120-12

5M (15FT)

VCTF2.0

AWG12

600W

50A

PSCS-0600-12**

15M (50FT)

VCTF5.5

AWG4

1000W

83A

PSCS-1000-12**

15M (50FT)

VCTF8.0

AWG2

EXTENSION OF POWER SUPPLY LEAD WIRES

*Maximum quantity for S-LED is based on 85% of specified capacity of power supplies for extended lifespan
**PSCS-0600-12, PSCS-1000-12 are not weather-proof
    Equip with protective box for outdoor use and the box should have ventilating holes

Make sure that each run should have 50 modules at max
and should use another run in parallel to connect more

Should use thicker wires which can take larger amount of current
than the amount transmitted from the power supply unit

Power Supply

AC Input

DC Output

30pcs

19pcs

60pcs

38pcs

120pcs

77pcs

610pcs

380pcs

1000pcs

650pcs

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

49th

50th