ENGLISH
ENGLISH
GB-39
GB-38
•
Do not dismantle the tap shafe: in the
event of a malfunction, change the
whole tap.
•
Before placing the burners back on the
top place, make sure that the injector
is not blocked.
•
A full operational test and a test for
possible leakages must be carried out
after gas conversion, (such as soap
water or gas detector)
•
After completing conversion, a
qualified technician or installer has to
mark “V” on the right gas category to
match with the setting in rating plate.
Remove the previous setting “V”
mark.
TROUBLE SHOOTING
• Repairs should be performed by a licensed
technician only.Improper repair may result in
considerable dangerto you and others.
• However, some minor problems can be
resolved as follows :
Problem
Probable cause
Solution
No ignition
No spark
Check the
electrical
supply
The cover of
the burner is
not assembled
correctly
Assemble the
cover properly
The gas supply
is disabled
Completely
open the gas
supply