SIGNALS
CAUSE
SOLUTIONS
- Does not fasten the rivet
- Non-powered tool
- Connect the riveting tools to the
compressed air
- Slipping of the clamps on the nail - Perform clamps maintenance
- Lack of oil
- Top up oil
- Incorrect nozzle
- Replace the nozzle as shown in
the table
- Unfiltered and unlubricated air
- Equip yourself with lubricator
filter assembly
- Oil leak
- Worn gaskets
- Contact the service center
- Oil filler cap not tightened
- Tighten correctly
- Air leak
- Incorrect positioning of the
feeding tube
- Position the feeding tube correctly
- Worn gaskets
- Contact the service center
- Breaks on the riveting machine
body
- Contact the service center
- Not ejected nail
- Incorrect nozzle
- Replace the nozzle as shown
in the table
TROUBLE ShOOTING