Multifunction power Meter instructions

WARNING! Please read the following instructions carefully before connecting this meter to electrical appliances.

Do not plug two or more meters together!

Indoor use only!

Not position the energy meter so that it is difficult to disconnect it from the supply!

iMportant

Don’t plug in an appliance where the load exceeds 16 Amp. Always ensure the plug of any appliance is fully inserted into the meter outlet. If cleaning of the 

meter is required, remove from mains power and wipe meter with a dry cloth.

KeYBoard definition

1. MASTER CLEAR: Clear all data in memory including current time and all programs.

2. UP: Set current time, price, price programs combined with buttons SET; exchange 12-24 hour mode during clock display state.

3. SET: Set current time, price, price programs combined with buttons UP.

4. FUNC: Exchange display state.

General features

 Display current clock.

1. 

 Display line voltage.

2. 

 Display line current.

3. 

 Display line power.

4. 

Display and memory accumulative total electric quantity.

5. 

 Display and memory total on time and total electric charge,.

6. 

 Display and memory total on time and total electric charge of price1.

7. 

 Display and memory total on time and total electric charge of price2.

8. 

Display line frequency.

9. 

Display power factor.

10. 

Adjustable price / kWh

11. 

11 combinations of day or blocks of days available as follows:

MO / TU / WE / TH / FR / SA / SU

MO,TU, WE, TH, FR

MO,TU, WE, TH, FR, SA

SA, SU

MO, TU, WE, TH, FR, SA, SU

BatterY

Insert the 3 pcs battery(LR44/AG13) according to the correct direction indication, close the cover of battery.Press master clear button after insert battery.now 

the power meter is now ready to be set up for use.

Note: 1. The cover must be in place before use.

          2. The battery must be taken out if not use for long time.

tHe data displaY

Press FUNC button the data displays as follows:

VOLTac  -> AMP  ->  WATT ->KWh  ->TOTAL PRICE;TOTAL ON TIME  ->  PRICE1->  PRICE2

1.The meter will display current clock and line voltage, frequency, if plug in socket after insert battery without any operation.

2. Press FUNC button once and release, the meter will display current clock and line current, power factor.

3. Press FUNC button once again and release, the meter will display current clock and real power, power factor.

4. Press FUNC button once again and release, the meter will display current clock and accumulative KWh,power factor.

5. Press FUNC button once again and release, the meter will display total on time and total electric charge.

6. Press FUNC button once again and release, the meter will display total on time of price 1 and total electric charge of price 1.

7. Press FUNC button once again and release, the meter will display total on time of price 2 and total electric charge of price 2.

8. Press FUNC button once again and release, the meter will come back to display current time and line voltage.

Press and hold FUNC button for 5 seconds to clear accumulative total electric quantity and total electric charge during display state of total electric 

charge or total electric charge of price 1 or total electric charge of price 2. 

9. LCD display ----when total electric quantity, total electric charge 

overflow, the OVER

 will flash at the same time.

settinG current clocK

Press FUNC button until the CLOCK displays in LCD.

1. 

Press SET button once time, The “WEEK DAY“will flash at same time, the clock change to SET mode. you can set the current clock now. 

2. 

Press UP button to set the “WEEK DAY“.

3. 

Press SET button once time again and release, The “HOUR“will flash.the “WEEK DAY“will stop flashing and keep display.

4. 

Press UP button to set the “HOUR“.

5. 

Press SET button once time again and release, The “MINUTE“ will flash. the “HOUR“will stop flashing and keep display.

6. 

Press UP button to set the “MINUTE“.

7. 

Press SET button once time again and release, the time come back to CLOCK display mode.

8. 

Press UP button during the CLOCK display state, change 12-24 hour mode.

9. 

To reset incorrect time, repeat above steps. After finish setting, Plug the meter into a regular 230 Volts power outlet, Plug in an appliance that you 

want to use and turn the mains power on. Now the meter begins to measure the consumption of the appliance and detect the equipment that uses too 

much electricity at once.

settinG price of cost/KwH

Press and hold FUNC button for 5 seconds during display state of voltage or current or power.

1.  Setting price 1:

a. Press SET button once and release, SET display, the first digital COST/kWh flash, press UP button to set it. 

b. Press SET button once again and release, the second digital COST/kWh flash, press UP button to set it.

c. Press SET button once again and release, the third COST/kWh flash, press UP button to set it.

d. Press SET button once again and release, the fourth COST/kWh flash, press UP button to set it.

e. Press SET button once again and release, the radix point COST/kWh flash, press UP button to set it.

f. Press SET button once again and release, the weekday flash, press UP button to set it.

g. Press SET button once again and release, the hour of ON TIME flash, press UP button to set it.

h. Press SET button once again and release, the minute of ON TIME flash, press UP button to set it.

2.  Setting price 2:

Press FUNC button once and release after finish Setting price 1. Setting price 2, repeat above steps.

stand BY Mode

Display of LCD will 

disappear without any operation after AC power off for 10 seconds. Press any key come back 

to display.

EN

231005-Manual-D.indd   3

11/06/14   14:45:37

Summary of Contents for 231005

Page 1: ...vous avez atteint la capacité maximum d affichage Remettre à zero les compteurs afin de repartir à zero REGLAGE DU COUT ENERGETIQUE Pour régler le TARIF 1 placez vous à l aide du bouton FUNC sur l affichage de la tension puis pressez le bouton FUNC durant 5 sec A l aide des boutons SET et UP indiquez le coût du KWh voir votre facture d éléctricité les jours concernés et l heure de début Réappuyez ...

Page 2: ...op op de spanning scherm en druk op de FUNC knop 5 seconden ingedrukt Met behulp van de SET UP toets en geef de kosten per kWh zie uw elektriciteitsrekening de betrokken dagen en de starttijd Druk nogmaals een keer op FUNC om op dezelfde manier de RATE 2 Het scherm wordt uitgeschakeld na een periode van niet gebruik van 10 s Druk op een toets om het te reactiveren ACCU Open het deksel Plaats 3 LR4...

Page 3: ...tton once again and release the meter will display total on time of price 2 and total electric charge of price 2 8 Press FUNC button once again and release the meter will come back to display current time and line voltage Press and hold FUNC button for 5 seconds to clear accumulative total electric quantity and total electric charge during display state of total electric charge or total electric c...

Page 4: ...epor a zero os contadores a partir do zero AJUSTE DE CUSTO DE ENERGIA Para definir a taxa de 1 fique com o botão FUNC no visor tensão e pressione o botão FUNC por 5 segundos Usando o botão Configurar e especificar o custo por kWh ver a sua factura de electricidade nos dias em questão ea hora de início Pressione novamente uma vez FUNC para definir o mesmo caminho da TAXA 2 O ecrã desliga se após um...

Page 5: ...alización Restablecer contadores a cero para comenzar de cero ENERGÍA COSTO DE AJUSTE Para establecer el TARIF 1 stand con el botón FUNC en la pantalla de voltaje y pulse el botón FUNC durante 5 segundos Usando el botón SET UP y especificar el coste por kWh ver su factura de electricidad los días que se trate y la hora de inicio Pulse de nuevo una vez FUNC para fijar la misma forma en que la TARIF...

Page 6: ...pacità di visualizzazione Azzera i contatori a zero per iniziare da zero ENERGIA COSTO REGOLAZIONE Per impostare la velocità di 1 stand con il tasto FUNC sul display della tensione e premere il tasto FUNC per 5 secondi Utilizzando il pulsante SET UP e specificare il costo per kWh vedere la tua bolletta elettrica i giorni in questione e l ora di inizio Premere di nuovo una volta FUNC per impostare ...

Page 7: ...CE şartlara uygundur odpovídá normám ES Cumple con la directivas de la CE È conforme alle direttive CEE Complies with the EEC standards Odpowiada normom UE Täyttää EU vaatimukset CE zodpovedá normám ES CE לתקני ועונה מתאים الأوروبية الدول مجموعة معايير يلبي و يطابق الجهاز بأن kielégíti a CE szabványok előírásait Je v skladu z in izpolnjuje norme Evropske skupnosti VERKLARING VAN OVEREENSTEMMING DE...