44
port (high level) disconnected trigger.
Alert message
sent to the server
Enable or disable the input port to send messages to the server
Send reset
message to server
Enable or disable sending reset messages to the server
Output Settings
Output port
response
Enable or disable output response
Output level
When low level (NO: open) is selected, when the trigger condition is met, the
trigger NO port is disconnected.
When the high level (NC: Close) is selected, the trigger NO port is closed
when the trigger conditions are met.
Output duration
The output port change duration, the default value is 5 seconds.
Alarm trigger setting
Output Response
Enable or disable Output Response
Output Level
When choosing the low level trigger (NO: normally open), when meet the
trigger condition, trigger the NO port disconnected.
When choosing the high level trigger (NO: normally close), when meet the
trigger condition, trigger the NO port close.
Remote DTMF
trigger
Receive the DTMF code sent by the remote device, and if it is correct, trigger
the corresponding output port.
You can choose to enable or disable the ringtone
DTMF trigger code
During the call, the receiving terminal device sends the DTMF code, and if it is
correct, the corresponding output port is triggered.
Reset code
After receiving the corresponding instruction, the test equipment will reset the
state and stop playing the corresponding ringtone
Active Uri trigger
Receive the active uri sent by the remote device, and if it is correct, trigger the
corresponding output port.
You can choose to enable or disable the ringtone
Trigger message
After the test equipment receives the corresponding instruction, if it is correct,
it will trigger the corresponding output port
Reset message
After receiving the corresponding instruction, the test equipment will reset the
state and stop playing the corresponding ringtone
Remote SMS
trigger
Enable or disable remote SMS triggering. You can choose to enable or
disable the ringtone
Trigger message
Send the command to ALERT = [command] on the remote device or server, if
it is correct, trigger the corresponding output port
Reset message
After receiving the corresponding instruction, the test equipment will reset the
state and stop playing the corresponding ringtone