Q1: What devices can T300 power?
A: Please note that the AC output port can only charge/power devices that operate at less than total 300 Watt.
Q2: Can the T300 be charged while using?
A: Yes, T300 supports pass-through charging. But we don't suggest, it will cause damage to battery life.
Q3: How to know the working times for my device? Why does the duration of some devices deviate from the actual usage data?
A: Working time = 299Wh* 0.85/operating wattage of your device. The duration of our equipment is based on laboratory data, and the duration of specific
equipment usage may vary.
Q4: Does T300 include a built-in MPPT controller?
10. TROUBLESHOOTING
A:
EVO300
power stations have a built-in MPPT controller.
Note: Storage instruction: fully charged every 3 months for best results and store it between -20 and 45 °C. Keep your portable power station away from heat and
direct sunlight in order to extend its life span.
Q5: Can it charge and discharge simultaneously?
Yes, but it is not recommended to charge and discharge at the same time in order to preserve battery lifespan.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Q6: How to extend the using time of CPAP?
Recommend to turn off its humidifier, heater, and set a lower pressure.
●
●
Q7: Can the AC output carry a refrigerator or air conditioner?
Workable for low power, and over 100W is not recommended. The starting power of refrigerators and air conditioners is generally 5~7 times higher than the rated
power, which easily triggers AC overload.
Q8: Can two power stations be used in parallel?
No.
If the product cannot charge or power other devices, please checking according to the following steps:
1. Make sure the power button is turned on.
2. Make sure the AC and DC power button are on.
3. Check the battery capacity, if it’s lower than 10%, please recharge the product as soon as possible.
4. Make sure the load power connected didn’t exceed the limit power of the product, each port has a limit for the power connected.
- 10 -