Fantom THE SPECIALIST SC925H Owner'S Manual Download Page 7

Water

Use tap water for all your cleaning 

needs.

However, if you live in an area with 

hard water, use de-mineralized / 

distilled water when steaming light 

colored fabrics to eliminate the 

possibility of hard water stains.

IMPORTANT: 

Do 

NOT

add cleaning 

solutions, scented perfumes, oils or any 

other chemicals to the water used in 

this appliance. 

Use tap water or 

distilled/purified water if the tap 

water in your area is very hard.

Efficient Work

• For vertical surfaces, wipe with a 

towel from the top down, in this 

way the dirty water will not soil 

surfaces already cleaned.

Avoid changing brushes back and 

forth while cleaning.

Start with the smallest brush to 

clean tight spots and corners first.

Use a towel to wipe dirt as soon as 

possible, otherwise it will dry and 

re-adhere to the surface.

If you consistently use demineralized or 

distilled water, cleaning the tank is 

unnecessary.

Rinsing Out the Steam Cleaner

Normally, a periodic rinse of your steam 

cleaner will free it from deposits.  This is 

recommended every 10-15 tankfulls, to 

free up any scale deposits from the tank.

Fill the boiler with 20 oz. of water and 

shake the cleaner vigorously.  Tilt the 

cleaner upside down to empty the boiler of 

water and any scale deposits.

Descaling Your Steam Cleaner

If the tap water in you area contains a high 

level of calcium deposits and you have 

been using tap water to do your steam 

cleaning, you should descale your unit 

after 10-15 tankfulls.

Step 1:

Unplug the steam cleaner from 

the power source before you 

descale the boiler. Allow to cool.

Step 2:

Fill the boiler with 1 part  

vinegar and 5 parts water and 

leave overnight or for a period 

of approximately 8 hours.  Do 

not screw  the safety/filler cap 

onto the steam cleaner while 

you are descaling the boiler. 

Do not use the steam cleaner 

while descaling solution is 

inside the boiler.

Step 3:

After the period of soaking, turn 

the steam cleaner upside down 

to empty solution from the 

boiler.  Due to the fact that a 

small amount of solution will be 

left in the boiler, it is necessary 

to rinse the boiler out with clean 

water 2 or 3 times.  Your steam 

cleaner is now ready for use.

Note:

When storing your unit, always 

drain any residual water in the boiler and 

do not tighten the safety filler cap onto the 

unit. Always leave the safety filler cap 

loose on the unit when not in use.

To Descale the Steam Cleaner

Care and Maintenance

TIPS ON HOW TO USE YOUR SYSTEM

OPERATING INSTRUCTIONS

Components

On/Off Switch: 

The unit is “On” when the 

switch is in the “Pushed down” position.  

The light on the On/Off switch will 

illuminate when the unit is on. The unit is 

“Off” when the switch is in its “Up” 

position.

Heating Light (red): 

This light will 

illuminate when the unit is heating up the 

water. 

Steam Ready Light (green): 

When this 

light is “On”, it indicates that the steam is 

ready to use.

Pressure Gauge: 

This helps you to 

monitor the steam pressure in the unit as 

you are working.

CAUTION:

Read the instructions 

for “Filling the Water Tank” before 

opening the Safety Cap. 

CAUTION:

Always unplug before 

filling. 

ALLOW  UNIT TO COOL 

FOR FIFTEEN (15) MINUTES 

BEFORE REFILLING.

IMPORTANT:  

Do 

NOT

add cleaning 

solutions, scented perfumes, oils or any 

other chemicals to the boiler in this 

appliance. 

Use tap water or 

distilled/purified water if the tap water 

in your area is very hard.

IMPORTANT:

Always insure that the 

unit is “

UNPLUGGED

” from the wall 

receptacle prior to initial filling or re-filling 

the water tank and has been allowed to 

cool for 15 minutes. 

Never attempt to fill 

this unit under a water tap

always use 

the filling funnel provided.

Fig. 1

Step 1:

Before refilling the steam cleaner, 

make sure that the unit is 

NOT

plugged in and has been allowed to 

cool for fifteen (15) minutes.

Step 7:  

Connect  desired attachments 

onto the flexible steam hose.

Step 8:

Plug the unit into a standard (120 

volt, grounded) wall receptacle. 

Allow approximately 15 minutes 

for vapor to reach its working 

temperature and pressure. The 

green ready light will illuminate 

when the unit is ready for use. 

Always point nozzle outlet in a safe 

direction.

NOTE:

When the steam cleaner has run 

out of water, steam output will 

cease. 

WARNING:

Allow 

unit to cool for 

15 minutes before refilling

.  

When refilling the steam 

cleaner while the boiler is still hot, 

there 

is a risk that water will squirt back 

during filling and cause scalding.  

Extreme care should be taken when 

refilling the unit. Use caution when 

opening the Safety/Filler Cap as cap 

may become hot during use and 

escaping steam can cause scalding.

Fig. 2

Assembly of Casters

The casters for your new steam cleaner 

are packed and shipped unassembled. 

To assemble the casters to the base of 

the steam cleaner, simply insert the 

caster stems onto one of the four (4) 

posts on the base and push downward 

with the palm of your hand. Repeat for 

the next three (3) casters.

Step 2:

Plug the power cord into an 

electrical outlet and press the 

steam switch on the 

hand grip to the 

“ON” position to

vent any residual 

steam that is in the 

boiler. (Fig 1)

Step 3:

Remove the power cord from the 

electrical outlet and turn the steam 

switch on the hand grip to the “OFF” 

position. (Fig. 1)

Step 4:

Place the unit on a flat, stable 

surface. Slowly turn the safety 

filler cap counter clockwise until it is 

removed.

Step 5

: Place the funnel in the tank 

opening as illustrated in Fig. 2. 

For optimum 

steam, it is 

recommended 

that no more 

than 84 US fluid 

ounces of water 

be added to a 

dry unit.  

Do Not Overfill

Step 6:

Replace the 

Safety Filler Cap.

Filling or Refilling Your Steam 

Cleaner With Water

8

5

Summary of Contents for THE SPECIALIST SC925H

Page 1: ...THE SPECIALIST PRO STEAM CLEANER OWNER S MANUAL Model SC925H A 120V 60 Hz 13 A 1550 W FANTOM 94 Main Mill Street Door 16 Plattsburgh NY 12901 Tel 1 800 275 9251...

Page 2: ......

Page 3: ...any appliance being used by or near children Do not leave the system unattended while connected 9 Burns can occur from touching hot parts hot water or steam Do not turn upside down as there may be ho...

Page 4: ...electrical appliances always unplug them from outlet before cleaning Do not direct steam into any openings of the appliances To clean counter tops use the nylon bristle brush For heavily soiled areas...

Page 5: ...athtub or shower area use the bristle brush for grout shower door tracks hard to get areas and heavily soiled areas The dual edge window tile squeegee will be the most efficient way to clean the rest...

Page 6: ...ly rubbing a small area as far down on the back or other out of the way place on the furniture as possible If color comes off on the towel you may need to have the piece dry cleaned Window Glass Surfa...

Page 7: ...d This light will illuminate when the unit is heating up the water Steam Ready Light green When this light is On it indicates that the steam is ready to use Pressure Gauge This helps you to monitor th...

Page 8: ...ents as many times the granules do not fully dissolve and become trapped in the towel This can scratch the surface that you are cleaning NEVER USE BLEACH OR FABRIC SOFTENERS Bleach will damage the mic...

Reviews: