Fantom FM741HR Instruction Manual Download Page 13

REPLACEMENT  INSTRUCTIONS

Caution:

    Be sure to turn the ON/OFF  switch to the"OFF" position and disconnect  the 

                  power  cord  from the wall outlet  before  replacing  any  of the parts below. 

REPLACING THE HEADLIGHT LAMP

1

Set the vacuum cleaner to the parallel  position.

2

  

  

  

 

  

  

Loosen the screws to remove the lens.

3

  

 

 

 

 

When removing the headlight lamp, be careful

  

  

  

  

   

 

 

not to pull on the headlight lamp wiring.

4

  

  

 

 

    

  

Remove the lamp by pushing it gently in

  

 

 

  

  

 

 

the direction of the arrow and then turning

 

it counterclockwise.

5

   

 

 

  

  

  

 

 

Push a new lamp gently into the socket and

  

   

  

turn it clockwise to tighten it .

    

  

  

  

 

Use a standard bayonet base appliance lamp

 

  

 

 

 

  

rated at 120V and 15W (LAMP MAX.15W).

 

  

  

  

  

  

 

Caution:

Be careful not to clamp the

                

  

 

headlight lamp wiring.

6

  

  

  

  

Reattach the lens and fasten the screws.

12

Socket

Screw

Lens

Headlight Lamp

2

1

Socket

2

1

Summary of Contents for FM741HR

Page 1: ...EANER USING THE ATTACHMENTS EMPTYING THE DUST COMPARTMENT CLEANING THE FILTERS CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY REPLACEMENT INSTRUCTIONS TROUBLESHOOTING REPLAC...

Page 2: ...l Street Door 16 Plattsburgh NY 12901 6 Do not pull or carry by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the vacuum cleaner...

Page 3: ...aner allow all internal metal parts to cool first 24 Always place foot on handle release when adjusting the handle position 25 If the supply cord of this appliance is damaged it must only be replaced...

Page 4: ...tion Hose A Dust Compartment Carrying Handle Duster Knob ON OFF Switch Release Button A Release Button B Release Button C Suction Hose B Filter Cover Wand Handle Release Lever Power Cord Upholstery To...

Page 5: ...ug to the wall outlet until assembly is completed Attaching the suction hose A attachments 4 1 2 Set the vacuum cleaner to the upright position lnsert the handle as shown in the illustration Handle Wa...

Page 6: ...ied electrician to install the proper outlet Do not modify the plug in any way 1 1 2 2 5 PREPARATIONS BEFORE USE WINDING THE POWER CORD Hook the power cord over the clip which is located on the upper...

Page 7: ...ositions Upright Normal Parallel Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright position position for storage or when using the attachm...

Page 8: ...selector to the RUG position When cleaning a bare floor or when using one of the attachments set the RUG FLOOR TOOLS selector to the FLOOR position Caution Do not change the setting of the RUG FLOOR T...

Page 9: ...older mount Holder Mount Hose Holder When you have finished using the attachments replace them in their original positions as shown on page 4 Tabs Groove Attachment Clamp Wand Crevice Tool Release But...

Page 10: ...dust compartment into the main body as shown to reattach 9 MAX mark 1 3 2 4 1 2 1 3 2 4 1 2 Trapdoor Projection Groove Release Lever Duster Knob Turn the duster knobseveral times in the direction sho...

Page 11: ...th a hair dryer or by placing in a clothes dryer Hot air may cause the filters to warp Reattaching the filters Insert the main filter into the prefilter as shown 10 The main filter and prefilter will...

Page 12: ...y clean the assembly Remove threads caught in the assembly by cutting them with scissors 11 Remove the bottom plate refter to page 14 Set the vacuum cleaner to the upright position Remove the hose cuf...

Page 13: ...When removing the headlight lamp be careful not to pull on the headlight lamp wiring 4 Remove the lamp by pushing it gently in the direction of the arrow and then turning it counterclockwise 5 Push a...

Page 14: ...gitator assembly and then remove the flat belt from the motor shaft and the agitator pulley Place a new flat belt onto the motor shaft and pulley Place the agitator assembly into the grooves in the no...

Page 15: ...late by pulling the tabs as illustrated REATTACHING THE BOTTOM PLATE Insert the projection on the bottom plate into the groove on the nozzle housing and set the bottom plate in place Push the bottom p...

Page 16: ...TRUCTIONS REPLACING THE FILTER Caution Do notwash the sub filter in a washing machine and do not use any other equipment such as a hair dryer to dry it Always allow 24 hours for drying Do not operate...

Page 17: ...e ON position Suction force is weak The agitator does not operate The power cord plug is not securely inserted into the wall outlet Insert the power cord plug securely into the wall outlet refer to pa...

Page 18: ...This warranty is extended to the original purchaser of the unit and excludes all other legal and or conventional warranties The responsibility of FANTOM if any is limited to the specific obligations e...

Reviews: