52
Technical features
-Temperature adjustment scale 2÷40 °C, increase 0.1°C
-Measurement scale/room T display: -50 ÷ +50 °C
-Thermal differential for regulation 0.3 ÷ 5.0 K
-Relative humidity adjustment scale: 30 ÷ 70%, increase 1%
-Measurement scale/room relative humidity display: 0 ÷ 100%
-Power supply: 2AA 1.5V alkaline batteries
-Transmission and reception frequency 868 MHz
-Maximum radio frequency power transmitted < 10 mW
-Relay contact range: 5(3)A / 250Vac – potential free contacts
-Type of action: 1BU (micro disconnection)
-Software: class A
-Thermal gradient of reference: 4K/h
-Maximum room temperature: 45 °C
-Electric insulation: double insulation
-Protection rating: IP40
-Pollution rating: 2
-Pulse voltage: 4000V
-Compliant with standards: EN 60730-1 and second parts
-Compliant with Directive 2014/53/EU (RED)
-ErP classi
fi
cation (EU Reg. 811/2013 - 813/2013):
-Class IV; 2%;
-Class VIII; 5% when used with O60RF actuators to create three or more heating zones.