OPERATING MODES
•
Unscrew front and back case with a screwdriver, than take off the front case (fig. 1)
•
Open relay case with screwdriver and take off the relay case (fig. 2)
•
Connect all wires properly (NC=normal close, NO=normal open, COM=common,
S1S2=terminals of the remote switch for the temperature reduction) (fig. 3, 8 e 9)
•
Cover the relay case and screw it properly with screwdriver (fig. 4)
•
Mount and fix back case in the wall with screwdriver (fig. 5)
•
Install 2x1,5 Vdc LR03 AAA (fig. 6)
•
Cover front case and back case properly (fig. 7)
It’s possible to choose two positions for the
jumper pin which fix the swing: 0,4 or 0,6°C.
The function is available only after RESET.
The thermostat always work in the continuous operating mode to the comfort tem
perature in the heating mode (the thermostat switch on/off the boiler).
When the boiler is on, will appear on the display the symbol
Set the comfort temperature through directly push on the display:
•
Push the display, the display willa come blue back light for 15 seconds
e n g l i s h
INSTALLATION
SWING
TEMPERATURE SETTING