Fantech SHL36 Instructions Download Page 3

Model

Location

Mounting

Airflow

Typical

at 0"

Airflow†

FX 8

interior

inline

481

430

FX 8XL

interior

inline

521

480

FKD 8XL

interior

inline

836

740

FKD 10XL

interior

inline

1266

1175

RVF 8XL

exterior

wall

435

392

RE 8XL

exterior

roof/wall

409

356

RE 10XL

exterior

roof/wall

753

730

SHL36

A

B

C

E

Duct

1" (25.4mm)

Dimmable

Halogen

Lights

Washable Aluminum Filters

Speed/Light

Controls

Wiring Location

3" (76.2mm)

4"

(101.6mm)

Front of hood

Model

UPC# 

Duct †

A

B

C

E

SHL36

47036

8

34 1/2

22

6

3

SHL42

47042

10

40 1/2

22

6

3

SHL48

47048

10

46 1/2

22

6

3

A

B

C

E

Duct

1" 

(25.4mm)

Dimmable

Halogen

Lights

Washable Aluminum Filters

Speed/Light Controls

Wiring Location

SGHL 30 & SGHL 36 Dimensions

7/8" (22.23mm)

2.25" 

(57.15mm)

SGHL30 - F=15" (381mm)

SGHL36 - F=18" 457.2mm)

Front of hood

F

Model

UPC# Duct †

A

B

C

E

SGHL30

47530

6

28 1/2

18

4

3

SGHL36

47536

8

34 1/2

18

4

3

SHL48

Model

Location

Mounting

Airflow

Typical

at 0"

Airflow†

FX 10

interior

inline

521

470

FX 10XL

interior

inline

590

540

FKD 10

interior

inline

910

780

FKD 10XL

interior

inline

1266

1060

FKD 12XL**

interior

inline

2016

1460

RE 10XL

exterior

roof/wall

753

720

Model

Location

Mounting

Airflow

Typical

at 0"

Airflow†

FX 6*

interior

inline

257

190

FX 6XL

interior

inline

392

275

FX 8XL

interior

inline

521

320

RE 6*

exterior

roof/wall

227

205

RE 8XL

exterior

roof/wall

409

356

RVF 6*

exterior

wall

242

200

RVF 6XL

exterior

wall

381

330

SGHL30

Model

Location

Mounting

Airflow

Typical

at 0"

Airflow†

FX 8XL

interior

inline

521

320

FKD 8XL

interior

inline

836

740

RE 8XL

exterior

roof/wall

409

356

RE 10XL

exterior

roof/wall

753

730

RVF 8XL

exterior

wall

435

392

SGHL36

Dimensions - 

All dimensional tolerances are 0” to 1/16 unless otherwise stated

Choosing the right remote mount blower

† Typical airflow is an estimate based on a system with 20' of duct, 

two 90˚ elbows, a backdraft damper, roof cap and filters.

* Fans will meet most local code requirements but will produce less 

than Fantech's recommended ventilation rate of 100 cm per foot of hood
width.

** Requires larger speed control. Contact Fantech Customer Service 

for recommendations.

3

Model

Location

Mounting

Airflow

Typical

at 0"

Airflow†

FX 8

interior

inline

481

430

FX 8XL

interior

inline

521

480

FKD 8XL

interior

inline

836

740

FKD 10XL

interior

inline

1266

1175

RVF 8XL

exterior

wall

435

392

RE 8XL

exterior

roof/wall

409

356

RE 10XL

exterior

roof/wall

753

730

SHL42

Reviews: