Fantech CM 3000 Installation, Operation And Maintenance Manual Download Page 10

10

fantech

  Warranty

• The maintenance free motors are 

permanently lubricated and are 
guaranteed for 7 years. They are 
factory balanced to prevent 
vibrations and promote silent 
operation.

• All other components have a 5 year 

limited warranty. (filters not included)

• The limited warranty covers normal 

use. It does not apply to any defects, 
malfunctions or failures as a result 
of improper installation, abuse, 
mishandling or misapplication, 
fortuitous occurrence or any other 
circumstances outside 
manufacturer's control.

• The warranty is in effect for 5 years 

on parts and 7 years on the motor 
after the date of purchase, including 
parts replaced during this time 
period. If there is no proof of 
purchase available, the date 
associated with the serial number 
will be used for the beginning of the 
warranty period. Parts are a 1 year 
warranty when replaced after the 
initial warranty has expired.

• This warranty is the exclusive and only 

warranty in effect and all other 
warranties either expressed or 
implied are invalid.

• Warranty from the manufacturer is 

for parts only and does not include 
labor or shipping to service or repair 
them.

Service

The useful service life of the filter media in the HEPA Filtration System is directly related to the 
volume of air passed through the system and the amount of contaminants in the air. In a typical 
residential application, Stage 1 and 2, filters should be replaced every three to six months or when 
needed. The Stage 3 HEPA filter should have a life span of two to five years, again, depending on 
the amount of particulate in the air and the maintenance of the Stage 1 pre-filter.

Parts list

Stage 1   -   Prefilter: Air passes through the prefilter where larger particles are taken out of the 

air. (part number  40195, also available in packs of 24 part numer 40196)

Stage 2   -   Carbon: Air passes through the carbon filter where some gases and odors are 

removed. (part number  40195, also available in packs of 24 part numer 40196)

Stage 3   -   HEPA: Air passes through the certified HEPA media where very small particles are 

removed. 99.97% of all particles 0.3 microns and larger that pass through this stage 
are removed. Particles smaller than 0.3 microns are also removed with less intensity. 
(part number  40193, also available in packs of 12 part numer 40194)

If the air flow through your unit is noticeably reduced, you can inspect the HEPA filter by removing it 
and seeing if the filter paper is darkened on the inlet or outer side. If it is, the filter cartridge should 
be replaced.

Please contact your local Fantech dealer or call HEPA Customer Service at 1.800.747.1762 
regarding replacement of filter media, warranty information or if you have any questions or 
concerns about the performance of your HEPA Filtration System.

Replacement parts number for motor (40323) .

Stage 1

Stage 3

Stage 2

Motor

Summary of Contents for CM 3000

Page 1: ...f the National Building Code and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www fantech net for more detailed technical information United States 10048 Industrial Blvd Lenexa KS 66215 T...

Page 2: ...fects Even reliable products will experience occasional failures and this possibility should be recognized by the user If these products are used in a life support ventilation system where failure could result in loss or injury the user should provide adequate back up ventilation supplementary natural ventilation or failure alarm system or acknowledge willingness to accept the risk of such loss or...

Page 3: ...TION 4 iNSTALLATION 5 CM 3000 Uninsulated model Option A 5 Option B 5 Option C 5 Option D 6 CM 3000 I Insulated model Option A 7 Option B 7 Option C 8 Option D 8 Whole House Connecting a ventilation system HRV ERV to HEPA system 9 SERVICE 10 PARTS LIST 10 MAINTENANCE SCHEDULE 11 ...

Page 4: ...ch as a basement closet or heated crawl space Example on page 5 6 The CM 3000 I Insulated version is normally installed in the southern U S states where it s common to locate the HVAC equipment in an unconditioned space such as a garage or attic Example on pages 7 8 Dimensions A B C D E F Model A B C D E F Duct Size Voltage Amp Delivery in mm in mm in mm in mm in mm in mm V Amps cfm CM 3000 16 4 5...

Page 5: ...e HEPA unit is operating at its full potential Installation CM 3000 Uninsulated model Option A B Diagrams are examples only Actual installation may vary The return side of the furnace is the recommended location for the HEPA to connect to The supply side is normally avoided due to the higher static pressure Furnace fan should operate continuous or when HEPA unit is on and running Options A B Optio...

Page 6: ...rams are examples only Actual installation may vary Unit can be installed in a closet Air drawn from a hallway or living area is cleaned by the HEPA unit and reintroduced back into a bedroom or other room Installation Cont d ...

Page 7: ...r when HEPA unit is on and operating Special care and attention must be given to ensure that all openings in unit and its duct connections are sealed to prevent vehicle exhaust from entering the unit Always follow local and state building codes as well as good engineering practices Option A Garage installation Option B Attic installation connected to return of or handler ...

Page 8: ...it should always be installed in a location that will allow the best possible access for service Flexible ducting can be restrictive to airflow and should be kept to a minimum Avoid excessive turns cramped ductwork and pinching Proper airflow should be confirmed after installation Option C Independently ducted Option D Independently ducted installation in crawled space 30 max recommended 16 5 of c...

Page 9: ...RV should be installed and balanced in accordance with its installation manual Furnace fan must be on when either the ventilation system HRV ERV or the HEPA filtration system is operating A power damper is recommended to prevent backdrafting of some models of air to air changers when in the off or standby position This damper will be installed between the HRV ERV and the HEPA unit Models Flex100H ...

Page 10: ...nts in the air In a typical residential application Stage 1 and 2 filters should be replaced every three to six months or when needed The Stage 3 HEPA filter should have a life span of two to five years again depending on the amount of particulate in the air and the maintenance of the Stage 1 pre filter Parts list Stage 1 Prefilter Air passes through the prefilter where larger particles are taken ...

Page 11: ...11 fantech Maintenance Date Type of Service performed Service Technician Schedule ...

Page 12: ...fantech Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...

Reviews: