HEPA Series

Air Filtration System

fantech

Installation, Operation and Maintenance Manual

Item #: 401482

Rev Date: 091914

Your Fantech HEPA Filtration system should be installed in conformance with the appropriate local, provincial or state 
requirements or in the absence of such requirements with the current edition of the National Building Code, and / or 
ASHRAE’s “ Good Engineering Practices”.

Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, 
components and specifications to maintain their technological leadership position. 
Please visit our website www.fantech.net for more detailed technical information.

United States

10048 Industrial Blvd., Lenexa, KS, 66215

Tel.: 800.747.1762 • 

Fax: 800.487.9915

Canada

50 Kanalflakt Way, Bouctouche, NB, E4S 3M5

Tel.: 800.565.3548 • 

Fax: 877.747.8116

Summary of Contents for CM 3000

Page 1: ...f the National Building Code and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www fantech net for more detailed technical information United States 10048 Industrial Blvd Lenexa KS 66215 T...

Page 2: ...fects Even reliable products will experience occasional failures and this possibility should be recognized by the user If these products are used in a life support ventilation system where failure could result in loss or injury the user should provide adequate back up ventilation supplementary natural ventilation or failure alarm system or acknowledge willingness to accept the risk of such loss or...

Page 3: ...TION 4 iNSTALLATION 5 CM 3000 Uninsulated model Option A 5 Option B 5 Option C 5 Option D 6 CM 3000 I Insulated model Option A 7 Option B 7 Option C 8 Option D 8 Whole House Connecting a ventilation system HRV ERV to HEPA system 9 SERVICE 10 PARTS LIST 10 MAINTENANCE SCHEDULE 11 ...

Page 4: ...ch as a basement closet or heated crawl space Example on page 5 6 The CM 3000 I Insulated version is normally installed in the southern U S states where it s common to locate the HVAC equipment in an unconditioned space such as a garage or attic Example on pages 7 8 Dimensions A B C D E F Model A B C D E F Duct Size Voltage Amp Delivery in mm in mm in mm in mm in mm in mm V Amps cfm CM 3000 16 4 5...

Page 5: ...e HEPA unit is operating at its full potential Installation CM 3000 Uninsulated model Option A B Diagrams are examples only Actual installation may vary The return side of the furnace is the recommended location for the HEPA to connect to The supply side is normally avoided due to the higher static pressure Furnace fan should operate continuous or when HEPA unit is on and running Options A B Optio...

Page 6: ...rams are examples only Actual installation may vary Unit can be installed in a closet Air drawn from a hallway or living area is cleaned by the HEPA unit and reintroduced back into a bedroom or other room Installation Cont d ...

Page 7: ...r when HEPA unit is on and operating Special care and attention must be given to ensure that all openings in unit and its duct connections are sealed to prevent vehicle exhaust from entering the unit Always follow local and state building codes as well as good engineering practices Option A Garage installation Option B Attic installation connected to return of or handler ...

Page 8: ...it should always be installed in a location that will allow the best possible access for service Flexible ducting can be restrictive to airflow and should be kept to a minimum Avoid excessive turns cramped ductwork and pinching Proper airflow should be confirmed after installation Option C Independently ducted Option D Independently ducted installation in crawled space 30 max recommended 16 5 of c...

Page 9: ...RV should be installed and balanced in accordance with its installation manual Furnace fan must be on when either the ventilation system HRV ERV or the HEPA filtration system is operating A power damper is recommended to prevent backdrafting of some models of air to air changers when in the off or standby position This damper will be installed between the HRV ERV and the HEPA unit Models Flex100H ...

Page 10: ...nts in the air In a typical residential application Stage 1 and 2 filters should be replaced every three to six months or when needed The Stage 3 HEPA filter should have a life span of two to five years again depending on the amount of particulate in the air and the maintenance of the Stage 1 pre filter Parts list Stage 1 Prefilter Air passes through the prefilter where larger particles are taken ...

Page 11: ...11 fantech Maintenance Date Type of Service performed Service Technician Schedule ...

Page 12: ...fantech Fantech reserves the right to make technical changes For updated documentation please refer to www fantech net Fantech ...