it, the possibility of an electric shock. 

Disconnect the power until the problem 

has been corrected.  

NOTE: This will reset the filter cycle.

230 VOLT, CONVERTED MODELS: 

•  A ground terminal is provided on the 

control box. To reduce the risk of electric 

shock, connect this terminal to the 

grounding terminal of your electrical service 

or subpanel with a continuous green, 

insulated copper wire. The wire must be 

equivalent in size to the circuit conductors 

supplying the equipment. In addition, a 

bonding terminal (pressure wire connector) 

is provided on the outside of the control 

box for bonding to local ground points. 

To reduce the risk of electric shock, this 

connector should be bonded with a No. 

8 AWG solid copper wire to any metal 

ladders, water pipes, or other metal within 

5 ft (1.5 m) of the spa to comply with local 

requirements. The means of disconnection 

must be readily accessible, but must be 

installed at least 5 ft (1.5 m) from the spa.

•  Your spa requires a suitably rated circuit 

breaker to open all ungrounded supply 

conductors.

•  Your spa must have a ground fault circuit 

interrupter in an electrical subpanel. Before 

each use of the spa and with the unit 

operating, push the TEST button on the 

breaker. The switch should click over to the 

“Trip” position. Wait 30 seconds and reset 

the GFCI breaker by switching it completely 

off and then completely on. The switch 

should then stay on. If the interrupter 

does not perform in this manner, it is an 

indication of an electrical malfunction 

and the possibility of an electric shock. 

Disconnect the power until the fault has 

been identified and corrected.

 IMPORTANT:

 Failure to wait 30 seconds 

before resetting the GFCI may cause the 

spa’s Power Indicator (on the control panel) 

to blink. If this occurs, repeat the GFCI test 

procedure.

   

DANGER: RISK OF 

ELECTRICAL SHOCK

•  Install spa at least 5 feet (1.5 m) from all 

metal surfaces. A spa may be installed 

within 5 ft (1.5 m) of a metal surface if each 

metal surface is permanently connected 

by a minimum No. 10 AWG solid copper 

conductor attached to the wire ground 

connector on the terminal box that is 

provided for this purpose if in accordance 

with National Electrical Code.

•  Do not permit any electrical appliances, 

such as a light, telephone, radio, or 

television within 5 ft (1.5 m) of a spa. 

Failure to maintain a safe distance may 

result in death or serious personal injury 

due to electrocution if the appliance should 

fall into the spa.

•  Install your spa in such a way that drainage 

is away from the electrical compartment 

and from all electrical components.

DO:

•  Be sure your spa is connected to the power 

supply correctly - use a licensed electrical 

contractor.

•  Disconnect the spa from the power supply 

before draining the spa or servicing the 

electrical components.

•  Test the Ground Fault Circuit Interrupter 

before each use.

DON’T:

•  Use the spa with the equipment 

compartment door removed.

•  Place electrical appliances within 5 ft 

(1.5m) of the spa.

• 

Use an extension cord to connect the spa 

to its power source. The cord may not be 

properly grounded and the connection is 

a shock hazard. An extension cord may 

cause a voltage drop, which will cause 

overheating of the jet pump motor and 

motor damage.

• 

Attempt to open the electrical control box. 

There are no user serviceable parts inside.

RISKS TO AVOID

SAFETY INFORMATION

Summary of Contents for Aspire

Page 1: ...OWNER S MANUAL...

Page 2: ...132 kg 190 gal 719 l 115 or 230V Enamor 4 81 206 cm 63 160 cm 33 84 cm 325 lbs 147 kg 260 gal 984 l 115 or 230V Enamor Premier 4 81 206 cm 63 160 cm 33 84 cm 365 lbs 166 kg 260 gal 984 l 115 or 230V E...

Page 3: ...RATION 11 OPERATIONAL MODES 12 SMART WINTER MODE 12 DIAGNOSTIC LCD MESSAGE 13 COMPONENT OPERATION SPACOMPONENT OPERATION 14 FILL UP AND START UP INSTRUCTIONS FILLING THE SPAWITH WATER 15 APPLYING POWE...

Page 4: ...ING THE RISK OF ELECTROCUTION Risk of Electrocution Connect only to a grounded source Do not bury the power cord A buried power cord may result in death or serious personal injury due to electrocution...

Page 5: ...e possibility of an electric shock Disconnect the power until the fault has been identified and corrected IMPORTANT Failure to wait 30 seconds before resetting the GFCI may cause the spa s Power Indic...

Page 6: ...nd circulation Persons taking medications which induce drowsiness such as tranquilizers antihistamines or anticoagulants should not use the spa Health problems affected by spa use Pregnant women shoul...

Page 7: ...installed where it is visible to the users of the spa IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and apply them DO Use and lock t...

Page 8: ...onsiderable amounts of moisture are produced This moisture can damage walls and ceiling surfaces over time Special paint is available to resist moisture damage Remember that spas periodically require...

Page 9: ...mize these effects it is best to provide plenty of ventilation to the spa area An architect can help to determine if more ventilation must be installed PLACING THE SPA CHECK THE DIMENSIONS OF YOUR SPA...

Page 10: ...rom wood panel then slightly remove wood siding from spa knowing light wires are still attached 2 Pull on each light wire to remove from base Remove wood panel from spa and set aside 3 Remove screws f...

Page 11: ...th the National Electric Code The disconnecting means must be readily accessible to the spa s occupant but installed at least 5 feet 1 5 m from the spa water 5 230V Power supply lines must be hard wir...

Page 12: ...O circumstances should an extension cord be used Use of an extension cord will seriously degrade the performance of the equipment and can create an electrical hazard 115 VOLT 30A OR 230 VOLT 50A PERMA...

Page 13: ...ude a properly rated GFCI circuit breaker The circuit must be dedicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire th...

Page 14: ...the low speed of the pump and again for the high speed Firmly press the Jets button again to turn off the pump If left running the low or high speed pump will automatically turn off after 1 hour The...

Page 15: ...IET MODE NT Maintains temperature with periodic sampling between the start of F1 and the end of F2 while not allowing any water sampling to happen between the end of F2 and the start of F1 To enter th...

Page 16: ...your dealer or service supplier if problem persists UPL No low level configuration software has been installed into the system Call your Dealer or service supplier FLO No water flow is detected by the...

Page 17: ...The diverter valve on your spa allows you to direct the flow of water from the pump to one of two combinations of jets The function of the diverter valve can best be learned by experimentation Turn th...

Page 18: ...ilure to keep enough water in your spa may result in damage to your system and invalidate your warranty If your spa filter is sucking in air causing the pump to cavitate you need to add water IMPORTAN...

Page 19: ...in small amounts a teaspoon at a time After adding one teaspoon wait one half hour before re measuring Once the safe range of total alkalinity is established proceed to the next step STEP 3 DETERMINE...

Page 20: ...et and weir out Unscrew the filter cartridge counter clockwise and bring it out of the spa requires many turns Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying wate...

Page 21: ...bristle brush Rinse thoroughly with cold water and air dry IMPORTANT Do not let the polyester dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and side flaps Rin...

Page 22: ...ft in the lines might freeze and damage the lines and jets 1 It will be necessary to remove all water from the interior plumbing 2 Remove the floating weir basket and filter cartridge Clean the filter...

Page 23: ...the air control valves counterclockwise and observe the increased jet action 3 Make sure the water level is half way between top of spa and top of the gray filter ring 4 Check for dirty filter Clean i...

Page 24: ...303554 24 A 9 23 1280 Park Center Drive Vista California 92081 888 961 7727 2023 WATKINS WELLNESS...

Reviews: