Fanmaster Ouber PAC500 Instruction Manual Download Page 5

Please solely use rated current of 10A socket!

                        

When in use in combination with other electrical 
appliances, the power socket or board may have 

abnormal heat, resulting in a fre

 3. Note in use

In order to prevent harm or damage to users and other people’s personal safety and 
property, please make sure to comply with the following:

This symbol, referring to please be careful - “ to draw attention to”

This symbol, referring to do not do - “ banned”

This symbol, referring to the need to implement - “ mandatory”

Non-authorised or non-qualifed personnel are 
not permitted to do repair or modifcation to 
this unit!

                           banned

 

Could lead to product failure or injury

Do not use voltage expectant AC220~240V 

± 10%!

 

      banned

Could cause a fre or electric shock

This machine should be used with single-phase 
two pole grounded electrical outlet and to ensure 
its reliable grounding! Grounding device is not 
installed, it could lead to airframe and other metal 
parts with electrostatic induction.

                          

                    Ensure grounding

PORTABLE EVAPORATIVE AIR COOLER

Could lead to product failure or leakage

Make sure to unplug the power plug from the 
socket when cleaning the water tank and cool-
ing pads, moving the machine or when not in 
use long periods.                

May result in an electric shock or damage

Use 0.15~0.6MPa water pressure! Temperature 
cannot exceed 45’C.              

 

     banned

May  result  in  the  cooling  pad  to  dissolve  and 
plastic  product deformation,  damage  and  affect 

the performance

Do not damage, destroy, over bend and twist the 
power cord. Please do not place heavy objects on 
the power cord. Ageing or damaged power cord 
must immediately be replaced or repaired by an 
authorised persons.

 

     

 banned

Easily cause damaged, fre and electric shock

3.

PORTABLE EVAPORATIVE AIR COOLER

 13. Cleaning & mainteance

TYPE

FREQUENCY

Changing the water

Weekly

1

Cleaning the flter screen

Monthly

1

Cleaning the cooling pads

Quarterly

1

*Please note in more dusty environments, the above schedule may need to occur on a 
more frequent basis.

CLEANING THE COOLING PAD AND FILTER SCREEN

*PLEASE ENSURE THE UNIT IS TURNED OFF AND UNPLUGGED FROM THE POWER SOURCE

1. use a screwdriver to unscrew 6 screws from the air-inlet louvre as per the 

image.
2. pull out the flter screen from the air-inlet louvre
3. hold the cooling pad and/or the flter screen and wash it down with a hose.

NOTE:
do not use a high pressure water hose as it may cause damage to the cooling pads

do not use detergents or soap to clean the cooling pads

10.

Take out the dustproof net upward

Summary of Contents for Ouber PAC500

Page 1: ...RTABLE EVAPORATIVE AIR COOLER INSTRUCTION MANUAL MODEL NO PAC500 NewTech Coolers by Fanmaster We reserve all rights of this manual We reserve the right to change or modify this manual without prior notice ...

Page 2: ...ed service or repair T o make a claim under the warranty take the product with proof of purchase to the store where you purchased the product or contact Fanmaster Pty Ltd Fanmaster Pty Ltd will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to Fanmaster Pty Ltd for consideration This warranty is given by Fanmaster Pty Ltd ...

Page 3: ...4 Check voltage Excessive noise 1 Fan blade dirty deformed or damaged 2 Motor wear 3 There are sundries blocking the outlet 1 Change fan blade or adjust bracket 2 Replace motor 3 Clear the sundries Fuse burnt out 1 Water pump damage 2 Synchronous motor damage 1 Replace water pump 2 Replace synchronous motor Water leakage 1 Machine on an unbalanced surface 2 Leaking from the tank 3 Drainage valve d...

Page 4: ... motor and the water pump both of which can be repaired at low cost and often by a mechanically inclined homeowner 4 V entilation air The constant and high volumetric fow rate of air through the building reduces the age of air in the building dramatically Evaporative cooling increases humidity In dry climates this may improve comfort and decrease static electricity problems The pad itself acts as ...

Page 5: ...nd cool ing pads moving the machine or when not in use long periods May result in an electric shock or damage Use 0 15 0 6MPa water pressure Temperature cannot exceed 45 C banned May result in the cooling pad to dissolve and plastic product deformation damage and affect the performance Do not damage destroy over bend and twist the power cord Please do not place heavy objects on the power cord Agei...

Page 6: ...ed by the manufacturer its service agent or similary by a qualifed persons in order to avoid a hazard 4 PORTABLE EVAPORATIVE AIR COOLER 12 Operating instruction 1 Make sure the voltage is in accordance with the local voltage before use 2 Connect the plug into the power source the machine will be in standby mode Press the ON OFF button to turn on and off Once turned off the machine will be in stand...

Page 7: ...LER assistance from an engineering design 5 Environment of use 1 Ambient temperature 25 C 45 C 2 Environment relative humidity 90 3 Water supply should make softening treatment 0 C temperature of water supply 45 C Pressure of water supply 0 15 0 6MPa 4 Deviation of voltage can not be more than 10 of rated voltage 5 No corrosive gases 6 No infammable and explosive gas or dust 6 Packing list Number ...

Page 8: ...et weight 46KG Applicable area m2 30 60 Air outlet dimension mm 160x690 Noise 70dB Water consumption 3 10L H Machine IP IPX4 7 Specifcations PORTABLE EVAPORATIVE AIR COOLER 8 Wiring diagram 6 PORTABLE EVAPORATIVE AIR COOLER 9 Brief diagram of structure 10 Parts list LCD Control Panel Fan Motor 0 55KW Water Sumbersible Pump Synchronous motor Water Float Filter screen black Cooling Pad Water Level S...

Reviews: