4. OPERATING INSTRUCTIONS - CONTINUED
4. OPERATING INSTRUCTIONS
START-UP
• Fill the tank with clean fuel. Only use Diesel or Kerosene
• The fuel gauge on top of the tank allows you to check the fuel level
• Connect the plug to the relevant power source
IDH2-20 & IDH2-30
• The power indicator will light up & the ambient temperature will display.
• Push the power switch to “ON”.
• If the thermostat control knob setting temperature is higher than the ambient
temperature, the electrodes will start sparking & after 7 seconds the heater will
start.
•
If the thermostat control knob setting is lower than the ambient temperature, turn
the thermostat control knob to the desired temperature setting. The electrodes
will start sparking & after 7 seconds the heater will start.
IDH2-50
•
The left display will show “- -”, the right display will show the ambient temperature.
• Push the power switch to “ON”.
•
The default temperature setting is 20’C (left display)
•
If the ambient temperature is lower than the default temperature, the electrodes
will start sparking & after 7 seconds the heater will start.
•
If the ambient temperature is higher than the default temperature, turn the
thermostat control knows to desired temperature. the electrodes will start
sparking & after 7 seconds the heater will start.
COLD START-UP
In low temperature, in Alpine/Highland/Inland regions, unseasonably cold weather.
Block the air vent hole on the air pump (see Fig. 4) by using your finger during ignition
to make start-up easier.
ABNORMAL OPERATION:
In case of malfunction (flame failure, reduced air flow, bad combustion) the heater
stops and the indicator light starts FLASHING (THE LOCK-OUT MODE code will be
showed on the display window).