background image

14

How to Operate Your Ceiling Fan (Continued)

3. 

 To make fan operational, install two 3V batteries 

(included) in hand-held remote transmitter, with fan 
power off. Then, follow the remote code setting process.  

    If not used for long periods of time, remove battery to 
    prevent damage to transmitter. Store the remote away 
    from excessive heat or humidly. (Figure 3)  

6. Remote Control Setting and Speed (RPM) 
    Setting Process : (Figure 4)

3V, CR2032
BATTERY

3V, CR2032
BATTERY

Figure 3

3V CR2032

Battery (2 pcs)

Figure 4

SET

Dip Switch

4. 

If you have multiple fans and want to program all fans  

to one handheld control, connect all fans to their power 
supply in the ceiling and follow Step 1 of the remote 
control set up process. Each fan needs to be no more than 
30 feet from the handheld control that you would like to 
program. Please note the wall switch that controls the 
power to your fan(s) should be in the off position until you 
are ready to program your handheld remote(s). 

 

 

5. 

If you have multiple fans and want to program each fan 

to separate handheld controls, connect one fan at a time to 
their power supply in the ceiling and follow Step 1 of the 
remote control set up process below. Before you connect 
the second fan to its power supply in the ceiling, you must 
disconnect the first fan that was wired and programmed 
from the power supply in the ceiling. Repeat these steps 
for each fan that you would like to program to a separate 
handheld remote. Please note that the wall switch that 
controls the power to your fan(s) should be in the off 
position until you are ready to program your handheld 
remote(s). 

      

1)

 After installing and wiring the unit, restore power to your 

fan by ensuring that the breaker and wall switch that 
controls the power supply is moved to the on position, 
press and hold the “SET” button inside of the battery 
compartment of the handheld remote control for 1-3 
seconds.      

2)

 You must press the “SET” button within 30 seconds of 

restoring power to the fan. 

 

 

 

 

3)

 When restoring power to your fan at the wall switch and 

breaker, DO NOT press any button(s) on the 
handheld remote control before pressing the “SET” button, 
otherwise the fan will fail the learn procedure.  

 

4)

 If you press any button(s) on the handheld remote 

control before pressing the “SET” button, please turn the 
wall switch that controls the power to the fan to the o  
position then on again, and start the process beginning 
with Step 1 above. 

 

 

 

 

 

5)

 When you press the “SET” button the fan will make two

musical sound and light will blink twice, and it has finished 
the control set up process. 

   

 

 

 

6)

 The fan is now ready for normal use.  

 

 

Summary of Contents for STELLAR 84

Page 1: ...roblems missing parts Before returning to your retailer call our customer service department at 1 888 567 2055 8 a m 5 p m EST Monday Friday Net Weight 18 74 lbs 8 50 kg STELLAR 84 ATTACH YOUR RECEIPT...

Page 2: ...e to a complete stop Additional Safety Instructions 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring and ins...

Page 3: ...our Ceiling Fan 10 9 How to Install Your Canopy Housing 11 How to Assemble Your Ceiling Fan Blades 11 How to Assemble Your Light Kit Assembly or Cap 12 How to Operate Your Ceiling Fan 13 17 How to Ins...

Page 4: ...supplied One stepladder One wire stripper One hex wrench not supplied WARNING Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not ha...

Page 5: ...entle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized...

Page 6: ...een two joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved...

Page 7: ...uts in the downrod support of the motor assembly Route the black white blue red gray and yellow wires and safety cable through the downrod Figure 3 4 Slide downrod into the downrod support on top of t...

Page 8: ...Figure 7 5 Route wires and safety cable through motor coupling cover canopy screw cover and ceiling canopy Figure 5 6 Reinstall the hanger ball on the downrod as follows Route the black white blue red...

Page 9: ...gh loop as possible Feed end of cable into clamp hole and firmly tighten screw Figure 4 Cut off excess safety cable r r r r r of 4 WARNING The fan must be hung with at least 7 of clearance from floor...

Page 10: ...cket as shown in Figure 2 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors Do not operate fan until the blades are in place Noise an...

Page 11: ...ed the motor assembly to have more spaces to tighten shoulder screws Fully assemble and tighten second shoulder screw that was previously removed Figure 1a How to Assemble Your Ceiling Fan Blades 1 Ca...

Page 12: ...y removed screws and secure all three screws Figure 4 How to Assemble Your Light Kit Assembly or Cap 12 Figure 1 Light Kit Light Kit Light Kit Wire Cover Figure 3 Figure 4 Light Kit Light Kit Figure 5...

Page 13: ...The receiver will automatically scan the frequency from the hand held control if any changes are made The frequency settings should only be changed in the case of interference or if multiple ceiling...

Page 14: ...he second fan to its power supply in the ceiling you must disconnect the first fan that was wired and programmed from the power supply in the ceiling Repeat these steps for each fan that you would lik...

Page 15: ...ght dimmer indicator Fan Speed button Tap once to turn off the fan Press and hold this button for 5 seconds to turn on or turn off the buzzer Light button Turn ON OFF the light Turn on fan and turn sp...

Page 16: ...artment of the handheld remote control WITHIN 30 seconds of restoring power to the fan 4 Pressing the SET button for 2 seconds will indicate if the fan is programmed to the remote control in hand 5 Th...

Page 17: ...the new fan to begin setup Figure 1 2 Press Save and your fan will be ready to operate Figure 2 Figure 2 3 Fan functions as show Figure 3 Figure 3 Name fo fan Fan setting indicators Speed Timer Light...

Page 18: ...th h s i n i f e h t g n i h c t a r c s d i o v a o t Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Periodic light dusting of the blades is recommended A...

Page 19: ...t the interior wall of the switch housing CAUTION Make sure main power is turned off 4 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not re...

Page 20: ...ontaining HDWMAD7993 Phillips screwdriver 4 Blade Mounting Hardware Bag Containing 10 24 Button Head Screw 33 pcs P799314 P799312 TR205 RECAN205SBT 7993 Light Kit Wire Cover 12 Hand Held Remote 10 Ste...

Page 21: ...21 1 2 3 4 5 6 7 8 9 11 12 NOTE The illustration shown is not to scale or its actua 10 13 13 Model MAD7993 Exploded View Illustration Stellar 84 13...

Page 22: ...Copyright 2018 Fanimation 2018 03 V 01 10983 Bennett Parkway Zionsville IN 46077 Phone 888 567 2055 Outside U S 317 733 4113 FANIMATION COM FAX 866 482 5215...

Page 23: ...ISTRE SU VENTILADOR EN FANIMATION COM LEA Y GUARDE ESTAS INSTRUCCIONES Peso neto 8 50 kg 18 74 lbs Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Serv...

Page 24: ...de estado s lido 6 Este ventilador es ideal para lugares secos y h medos 7 PARA REDUCIR EL RIESGO DE DESCARGAS EL CTRICAS ESTE VENTILADOR SE DEBE INSTALAR CON UN CONTROL INTERRUPTOR DE PARED AISLADO A...

Page 25: ...Fanimation 8 Fanimation se reserva el derecho de modificar o discontinuar un producto en cualquier momento o sustituir cualquier pieza seg n lo establecido por esta garant a 9 En ning n caso se podr...

Page 26: ...rt is damaged or missing This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Fanimation Substitution...

Page 27: ...tinuaci nlepresentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habi...

Page 28: ...de que la electricidad est desconectada en la caja de fusibles principal antes de realizar la instalaci n el ctrica Toda instalaci n el ctrica debe cumplir con los c digos nacionales y locales y el ve...

Page 29: ...6 Figura 1 4 Coloque el soporte de la varilla y alinee los orificios de la clavija de horquilla en ambas piezas Instale la clavija de horquilla y aseg rela con la pinza de horquilla Instale los set d...

Page 30: ...a techo a trav s de la semiesfera Pase el pasador a trav s de los dos orificios en el barral y alinee la semiesfera de modo que el pasador quede atrapado en la ranura de la parte superior de la misma...

Page 31: ...bien asentada contra la caja de salida Si la caja de salida est empotrada retire el panel hasta que la abrazadera haga contacto con la caja Si la abrazadera y o la caja de salida no est n bien asegur...

Page 32: ...ntilador Figura 1 ADVERTENCIA 3 Cuando haya realizado las conexiones ponga los cables blancos y verdes en un lado y los cables negros hacia el otro lado Los cables deben ser colocados de forma extendi...

Page 33: ...de que los cables el ctricos se encuentren completamente adentro de la cubierta del capuch n y de que no est n aprisionados entre la cubierta y el techo ADVERTENCIA NOTA Este paso se debe realizar lu...

Page 34: ...B Opci n B Para su uso con la tapa de acer Si desea instalar la tapa de acero y no el conjunto de luz Monte el la tapa de acero en la kit de luz del interruptor gir ndolo en el sentido de las agujas d...

Page 35: ...funci n de aprendizaje autom tico No hay interruptores de frecuencia en la unidad del receptor El receptor ya que se escanear autom ticamente la frecuencia desde el mando a distancia si se realiza cu...

Page 36: ...del disyuntor y del interruptor de pared NO pulse ning n bot n en el mando a distancia hasta que haya pulsado el bot n SET ya que de lo contrario el ventilador perder el proceso de aprendizaje 4 Si p...

Page 37: ...hacia abajo sin una brisa visible 8 Posici n de bloqueo El motor CC posee una funci n de seguridad integrada para evitar la obstrucci n de las palas durante el funcionamiento del ventilador Si algo o...

Page 38: ...s del mando a distancia EN MENOS DE 30 segundos despu s de haber suministrado la electrici dad al ventilador 4 Al pulsar el bot n SET durante 2 segundos indicar que el ventilador est programado al man...

Page 39: ...gura 1 2 Pulse Guardar y su ventilador estar listo para ser utilizado Figura 2 Figura 2 3 Las funciones del ventilador se muestran Figura 3 Figura 3 Nombre del ventilador Indicadores del ajuste del ve...

Page 40: ...ren agentes abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado PRECAUCI N No utilice solventes para limpiar el ventilador de techo Podr an da ar el motor o las aspas y o...

Page 41: ...barral 2 La bola colgante con ranura no est alineada con la pesta a 2 Vuelva a colgar la bola colgante para asegurar la pesta a en la ranura est n flojos 3 El tornillo de fijaci n en la unidad del bar...

Page 42: ...ista de piezas Antes de desechar los materiales de embalaje aseg rese de haber extra do todas las piezas Inserte los C DIGOS DE ACABADO consulte el n mero de modelo del ventilador que se encuentra en...

Page 43: ...13 43 1 2 3 4 5 6 7 8 9 11 12 10 13 13 Modelo MAD7993 Stellar 84 Ilustraci n del despiece NOTA La ilustraci n que se muestra no est hecha a escala y su c guraci n real y o terminaci n puede variar...

Page 44: ...ro sitio Web en www fanimation com 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Copyright 2018 Fanimation 2...

Reviews: