How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical wiring 
knowledge or experience, have your fan installed by a 
licensed electrician. 

1. 

Run the blue, black and white fan wires through the 

wiring hole in the side of the hanger bracket to allow for 
electrical connections. 

2. 

Connect the green grounding wire from the hanger 

bracket and hanger ball to the grounding wire from the 
outlet box (this may be a bare wire or a wire with green 
insulation). Securely connect these three wires with wire 
connectors supplied with your fan. 

3.  

Securely connect the white wire from the fan motor 

to the white supply (neutral) wire using wire connector 
supplied (Figure 1).

4.  

Securely connect the black fan motor wire and blue 

wire to the black supply wire using wire connector supplied 
(Figure 1). 

NOTE: 

  If you are using a Fanimation Light Fixture with 

your fan, see Ceiling Fan Light Kit Installation Instructions 
for wiring. 

5. 

After connections have been made, turn leads upward 

and carefully push leads into the outlet box, with the white 
and green leads to one side of the box and the black and 
blue leads towards the other side. 

6. 

After all electrical connections are made, secure the 

ceiling canopy to the hanger bracket with the threaded 
rods, lockwashers and knurled knobs provided (see page 
10).
 

7.  

Prior to attaching blades, check to see that all connections 

are tight, including switch caps located on ends of motors 
and below the connecting harness.

120 VAC 

Supply

(User 

Supplied)

Black Wire (Hot)

White

(Neutral)

Blue Wire 

(Light 

Fixture)

Green Wire 

(Ground)

(To/From 

mounting

  bracket)

Wiring and Control Options

Please choose one of the following options and proceed to 
the page as indicated.

1.

  Standard 4-position, 2-speed, fan-only C3 wall control, 

see page 8.

2.

  Optional fan & light slide wall control (C6). Please see 

instructions provided with control. 

NOTE:

 If you are using a Fanimation Light Fixture with your fan, see Ceiling Fan Light Kit Installation Instructions (packed 

with light kit) for wiring.

Figure 1

3.

  Optional fan & light remote control receiver unit (SW24), 

to be used in conjunction with: C24 hand-held remote 
control and/or C25 wall-mount remote control  Please see 
instructions provided with control.

INSTALLATION NOTE

If separate control of light fixture (optional) is desired, 

a separate switch leg from the outlet box is required. In 

this instance the blue wire from the fan will be connected 

to the light switch leg (typically red wire)

WARNING

Check to see that all connections are tight, including 

ground, and that no bare wire is visible at the wire 

connectors, except for the ground wire.  Do not operate 

fan until the blades is in place.  Noise and fan damage 

could result.

WARNING

To avoid possible electrical shock, be sure electricity is 

turned off at the main fuse box before wiring.

NOTE: If you are not sure if the outlet box is grounded, 

contact a licensed electrician for advice, as it must be 

grounded for safe operation.

Summary of Contents for Palisade FP240 Series

Page 1: ...ANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP240 The Palisade Ceiling Fan Standard Damp Location Models Damp Location Model Top of fan is marked Suitable For Use In Damp Locations Net Weight 21 k...

Page 2: ...ce panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service pa...

Page 3: ...ade to Hub Mount g Hardware Bag Seventeen 10 32 x screws Hanger Ball Adapter Assembly Ceiling Canopy Hanger Bracket Assembly 2 speed C3 wall control Ceiling Canopy Hanger Bracket Assembly 2 speed C3 W...

Page 4: ...Loosen Loosen Figure 2 WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electri...

Page 5: ...d the blade holders when installing balancing the blades or cleaning the fan Do not insert foreign objects in between the rotating blades This Lag Bolt is fastened securely Hanger Bracket is loose and...

Page 6: ...ure 2 4 Carefully ROTATE the Hanger Bracket and Crossbar Pole Assembly together to orientate the fan in the desired position Figure 2 5 Carefully remove the Crossbar Pole Assembly from the Hanger Brac...

Page 7: ...acket Figure 3 6 Attach the safety cable to ceiling support cable Slide cable clamp onto safety cable from fan Place the end of cable through the loop of ceiling support cable Pull as much cable throu...

Page 8: ...e tight including switch caps located on ends of motors and below the connecting harness 120 VAC Supply User Supplied Black Wire Hot White Neutral Blue Wire Light Fixture Green Wire Ground To From mou...

Page 9: ...Make wiring connections with wire nuts as shown in Figure 1 One black wire from wall control unit to black hot supply One black wire from wall control unit to black wire leading to ceiling outlet box...

Page 10: ...am Pad Adhesive Side Down Screw 14 mm 2 per blade supplied with PADKT Figure 2 Side A Fan Blade Side B PADKT Instructions PADKT Foam Pad Set is Supplied in PADxx Blade Set Cartons Only Foam Pads Must...

Page 11: ...hite dot 4 pcs These colored dots indicate which motor switch set up red or white dot to attach these blade holders to 2 Using the HDWBH240 Blade Holder to Hub screws attach the blade holders to the c...

Page 12: ...nly a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish CAUTION Do not use water when cleaning yo...

Page 13: ...ll of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state controls are not recommended choose...

Page 14: ...ag Bolt for Support Cable Mounting Hardware Bag Containing HDWFP240 3 20 x Screw 4 6 5 32 32 x 1 Threaded Rods 2 5 32 External Lockwasher 2 5 32 32 Knurled Knobs 2 22 Allen Wrench 5 mm 23 3 8 x 2 Lag...

Page 15: ...ation shown is not to scale or its actual configuration may vary wires omitted for clarity Exploded View Side B Side A 16 12 1 11 17 13 14 20 18 19 10 4 7 16 6 3 2 The Palisade FP240 Figure 1 5 8 8 9...

Page 16: ...Copyright 2007 Fanimation 2007 05 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S 317 733 4113 Visit Our Website www fanimation com...

Reviews: