Fanimation MAD3250 series Owner'S Manual Download Page 4

This manual is designed to make it as easy as possible for you

to assemble, install, operate, and maintain your ceiling fan

Unpacking Instructions

For your convenience, check-off each step.  As each step is completed, place a check mark.  This will ensure that all 
steps have been completed and will be helpful in  finding your place should you be interrupted. 

Wiring outlet box and box connectors must be of type 
required by local code.  The minimum wire would be a 3-
conductor (2-wire with ground) of the following size:

NOTE:  Place the parts from the loose parts bags in a small 
container to keep them from being lost.  If any parts are missing, 
contact your local retailer.

Tools Needed for Assembly

Materials

Wire Size A.W.G.

Installed Wire Length

14
12

Up to 50 ft.

50 - 100 ft.

NOTE:  If you are uncertain of part description, refer to
exploded view illustration. 

4

1.

Check to see that you have received the following 

parts:

Hardware Bag

Fan Motor

Assembly

Downrod/

Hanger Ball

Assembly

Ceiling Canopy

‡2QH3KLOOLSVKHDGVFUHZGULYHU
‡2QHVWHSODGGHU
‡2QHó´

 blade screwdriver

‡2QHZLUHVWULSSHU
‡

Four wire connectors

  (supplied)

WARNING

Do not install or use fan if any part is damaged or 
missing.  This product is designed to use only those 
parts supplied with this product and/or any accessories 
designated specifically for use with this product by 
Fanimation.  Substitution of parts or accessories not 
designated for use with this product by Fanimation could 
result in personal injury or property damage.  Contact 
your retail store for missing or damaged parts.

WARNING

Before assembling your ceiling fan, refer to section on 
proper method of wiring your fan (page 10). If you feel you  

 

do not have enough wiring knowledge or experience, 
have your fan installed by a licensed electrician.

‡)DQ0RWRU

 Assembly

‡+DQJHU%UDFNHW$VVHPEO\

‡'DQJHU%DOO

  Assembly

‡&HLOLQJ&DQRS\

‡0RWRU&RXSOLQJ&RYHU$VVHPEO\

‡RXVLQJ&DS$VVHPEO\

‡%ODGH+ROGHU

Set

‡%ODGH+ROGHU&RYHU6HW

‡DQG+HOG

‡&DQRS\6FUHZ&RYHU$VVHPEO\

‡+DUGZDUHEDJ
±(OHYHQó´[PP

       (blade holder to fan motor hub)
       screws with lockwashers
    – Eleven 

3

16

-24 x 10 mm (blade

       to blade holder) phillips-head 
       screws 
    – Three wire connectors

±%DODQFH.LW

±3KLOLSV6FUHZGULYHU´

±%DJ$VVHPEO\6DIHW\&DEOH

Hanger Bracket
Assembly

Motor Coupling 

Cover Assembly 

Canopy Screw

Cover Assembly

Switch Housing 
Cap Assembly

Remote Hand Held

Blade Holder Set 

Blade Holder Cover Set

Summary of Contents for MAD3250 series

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS The Islander Ceiling Fan Net Weight 6 37 kg 14 04 lbs Model No MAD3250 R...

Page 2: ...f at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning devic...

Page 3: ...w to Assemble Your Ceiling Fan 7 How to Hang Your Ceiling Fan 9 How to Wire Your Ceiling Fan 10 Installing the Canopy Housing 11 How to Operate Your Ceiling Fan 13 Assembling and Mounting the Fan Blad...

Page 4: ...U Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This product is designed to use only those parts supplied with this product and or any accessories d...

Page 5: ...gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realize...

Page 6: ...box with brace Figure 3 Paired with a deep box this hanger is meant to span between two joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully A...

Page 7: ...e l c e h t n g i l A r e l p u o c o t n i d o r n w o d l l a t s n I holes in the downrod with the holes in the downrod support Figure 2 3 Install the clevis pin hairpin clip and tighten set screw...

Page 8: ...and retightened where necessary before installation Canopy Screw Cover Ceiling Canopy Motor Coupling Cover Figure 4 Figure 5 5 Reinstall the hanger ball on the downrod as follows Route the two 80 in...

Page 9: ...ll pass through the washer safety cable loop and into the building structure Figure 9 NOTE Ceiling support cable cannot be secured to junction box only it must be directly secured to ceiling joist or...

Page 10: ...Ground Listed Outlet Box Household Supply Black Wire from Supply Black Wire from Fan x 3 WIRE CONNECTORS HARDWARE USED NOTE If you feel that you do not have enough electrical wiring knowledge or expe...

Page 11: ...and Mounting the Fan Blades Do not connect fan blades until the fan is completely installed Installing the fan with blades assembled may result in damage to the fan blades CAUTION x 10 3 16 24 x 10 m...

Page 12: ...ure the screws with lockwashers securing the blade holders to the fan motor hub are tight and that the blade holders are properly seated Figure 16 Figure 17 Switch Housing Cup Assembly 3 Disassemble t...

Page 13: ...remote away from excessive heat or humidly Figure 21 NOTE Receiver in controllers system features an automatic learning function There are no frequency switches on the receiver unit The receiver will...

Page 14: ...dium low speed IV medium speed V medium high speed VI high speed Button This button turns the fan off Reverse button This button is to control fan direction The button is to control light Infinite lig...

Page 15: ...EO 3 Canopy 1 DQJHU UDFNHW 6FUHZ VVHPEO CDQRS 6FUHZ RYHU VVHPEO 4 0RWRU RXSOHU RYHU VVHPEO 5 0RWRU VVHPEO 6 ODGH ROGHU RYHU 6HW 7 ODGH ROGHU 6HW 8 9 10 6ZLWFK RXVLQJ DS VVVHPEO Remote Hand Held ADR1 6...

Page 16: ...NOTE The illustration shown is not to scale or its actual parts configuration may var y Exploded View Illustration 16 MAD3250 3 4 5 6 9 7 11 8 1 10 2 12...

Page 17: ...ommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew in downrod hanger ball assembly is loose 3 S...

Page 18: ...Copyright 2014 Fanimation 2014 03 V 01 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Page 19: ...Ventilador de techo Peso neto 6 37 kg 14 04 lb MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Modelo N MAD3250 The Islander R...

Page 20: ...onales Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles antes de realizar 1 la instalaci n el ctrica y no haga funcionar el ventilador...

Page 21: ...os no permiten limitaciones sobre las garant as impl citas Fanimation no se har responsable por da os accidentales resultantes o especiales derivados del uso o el rendimiento del producto o en conjunc...

Page 22: ...los conocimientos el ctricos necesarios contrate a un electricista autorizado para instalar el ventilador LD FDMD GH GLVWULEXFLyQ HO FWULFD ORV FRQHFWRUHV GH OD FDMD GHEHQ VHU GHO WLSR UHTXHULGR SRU H...

Page 23: ...tinuaci nlepresentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habi...

Page 24: ...a autorizado ADVERTENCIA Apagar el interruptor de pared no es suficiente Para evitar posibles descargas el ctricas aseg rese de que la electricidad est desconectada en la caja de fusibles principal an...

Page 25: ...os orificios del soporte del mismo Figura 2 3 Instale el pasador y el pasador de horquilla y apriete los tornillos de fijaci n El pasador y el pasador de horquilla deben estar instalados correctamente...

Page 26: ...Se deben revisar todos los tornillos de fijaci n y volver a ajustarlos cuando sea necesario antes de realizar la instalaci n Figura 5 5 Vuelva a colocar la semiesfera en el barral como se indica a con...

Page 27: ...la leng eta de la abrazadera para colgar Figura 10 NOTA el cable de soporte para techo no se puede asegurar solamente a la caja de conexiones se debe asegurar directamente a la viga de techo o miembro...

Page 28: ...ue todas las conexiones est n ajustadas incluida la conexi n a tierra y que no haya conductores desnudos visibles en los conectores excepto el conductor con conexi n a tierra No opere el ventilador ha...

Page 29: ...NOTA Encontrar que la pala del ventilador viene empaquetada en su propio envoltorio de cart n y que las sujeciones de las palas y la bolsa del hardware vienen en la caja del ventilador Cubierta del so...

Page 30: ...los tres tornillos del soporte ubicado en la parte inferior de la unidad del motor Afloje levemente los otros dos tornillos Instale la unidad de la placa de luz en el soporte utilizando las dos ranur...

Page 31: ...de aprendizaje autom tico No hay interruptores de frecuencia en la unidad del receptor El receptor ya que se escanear autom ticamente la frecuencia desde el mando a distancia si se realiza cualquier c...

Page 32: ...ON es la selecci n regulable de luz y debe ser utilizada con todas las bombillas menos con las bombillas CFL La selecci n D es la encender solo la luz sin la funci n de regulaci n y debe ser utilizada...

Page 33: ...ho Podr an da ar el motor o las aspas y ocasionar posibles descargas el ctricas SE RECOMIENDA veri car peri dicamente que los tornillos que sujetan los soportes de aspas al buje del motor est n bien a...

Page 34: ...zas Destornillador Phillips de 4 Antes de desechar los materiales de embalaje aseg rese de haber extra do todas las piezas Inserte los C DIGOS DE ACABADO consulte el n mero de modelo del ventilador qu...

Page 35: ...3 4 5 6 9 7 11 8 1 10 2 12 35 MAD3250 NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar Ilustraci n del Despiece...

Page 36: ...no son recomendables Escoja un m todo de control alternativo 6 Ajuste bien los tornillos 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijaci n y la tuerca del soporte de barral est n flojos 2 El...

Page 37: ...014 Fanimation 2014 03V 01 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fan...

Reviews: