Maintenance

Periodic cleaning of your new ceiling fan is the only 

maintenance that is needed. When cleaning, use only a 

soft brush or lint free cloth to avoid scratching the 

fi

 nish.

Abrasive and/or non-abrasive cleaning agents are not 

required and should be avoided to prevent damage to 

fi

 nish.

CAUTION

Do not use water when cleaning your ceiling fan. It could 

damage the motor or the finish and create the possibility 

of electrical shock. 

Trouble Shooting

WARNING

For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.

Trouble

Probable Cause

Suggested Remedy

1.  FAN  WILL  NOT  START

1.

  Fuse or circuit breaker blown.

2.

  Loose power line connections to the fan, or loose 

switch wire connections in the switch housing.

3.

  Dead battery in remote control.

1.

  Check main and branch circuit fuses or circuit 

breakers.

2.

  Check line wire connections to fan and switch wire 

connections in the switch housings.

 

CAUTION: Make sure main power is turned off !

3.

  Replace with fresh battery.

2.  FAN  SOUNDS  NOISY

1.

  Motor noise caused by solid state variable speed 

control.

1.

  Some fan motors are sensitive to signals from 

solid-state variable speed controls.  Solid-state controls 

are not recommended, choose an alternative control 

method.

3.  FAN  WOBBLES

     EXCESSIVELY

1.

  Setscrew in downrod support is loose.

2.

  Setscrew in downrod/hanger ball assembly is loose.

3.

  Hanger bracket and/or ceiling outlet box is not  

securely fastened.

1.

  Tighten both setscrews securely in downrod support. 

2.

  Tighten the setscrew in the downrod/hanger ball 

assembly. 

3.

  Tighten the hanger bracket screws to the outlet box, 

and secure outlet box. 

Summary of Contents for Enigma FP2120 Series

Page 1: ...Enigma Ceiling Fan Suitable for use with Solid State Speed Controls WARNING Support Directly From Building Structure Net Weight 38 lbs or 17 3 kg For Canada this fan must be secured directly to the b...

Page 2: ...onjunction with product use or performance except as may otherwise be accorded by law This warranty gives you special legal rights and you may also have other rights that vary from state to state 10 A...

Page 3: ...32 threaded rods Two 5 32 lockwashers Two 5 32 knurled knobs Support Cable bag Ceiling Support Cable Cable Clamp x 2 lag bolt flat washer Lower Cover Assembly Lower Cap C4 Fan Light Remote Control Rem...

Page 4: ...Control Housing Figure 1 Line up the indexing holes over the screws secure by twisting the Lower Cover Assembly clockwise and tighten the two indexing screws Figure 2 5 Turn the Ceiling Fan Assembly...

Page 5: ...e straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed...

Page 6: ...an be made later 4 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger bracket that was just attached to the ceiling joist Be sure the groove in the ball is lined up with ta...

Page 7: ...not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 2 Installing Receiver in Hanger Bracket Slide remote Receiver into the Hanger Bracket Figure...

Page 8: ...page 7 NOTE Supply wires and fan wires omitted for clarity 1 To install lower cap screw in lower cap into bulb socket until tight Figure 3 3 Restore power Figure 2 WARNING To avoid possible fire or s...

Page 9: ...tch wire connections in the switch housing 3 Dead battery in remote control 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections i...

Page 10: ...eaded Rods 2 5 32 External Lockwashers 2 Knurled Knobs 2 Wire Connectors 3 Support Cable Bag Containing HWBSCABLE Ceiling Support Cable Cable Clamp Flat Washer x 2 Lag Bolt 9 Receiver Unit RECAN34 10...

Page 11: ...2a 2b 2c 2d 2 8 7 6 4 5 3 9 1 10 11 NOTE The illustration shown is not to scale or its actual configuration may vary Wires partially removed for clarity Exploded View The Enigma FP2120 Figure 1...

Page 12: ...10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Visit Our Website www fanimation com Copyright 2007 Fanimation 2007 08...

Reviews: