Fanimation EMBRACE FPS7955B Manual Download Page 2

1.   LIMITED LIFETIME MOTOR WARRANTY - If any part of your fan motor fails, due to a defect in materials or workmanship during 

the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned

to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

2.   ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to 

defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser 

will be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 

reinstallation and shipping of the product for repairs or replacement.

3.   If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we 

will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

4.   Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding,

tarnishing, or peeling.

5.  This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of 

heat or humidity, or as a result of any modification to the original product.

6.   All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 

or Fanimation.

7.   Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

8.   Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must ac-

company authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid

damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

9.   It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 

implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 

fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation

will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance,

except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that vary 

from state to state.

10. A certain amount of wobble is normal and should not be considered a problem or a defect.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

1.   Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.

2.   Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, such

as a tag, to the service panel.

3.   Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan before 

servicing.

4.   Do not insert anything into the fan blades while the fan is operating.

5.   Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions

1.   To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.   All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70) and Local Codes. The ceiling fan  

 

must be grounded as a precaution against possible electrical shock.  Electrical installation should be made or approved by a licensed

electrician.

3.   The fan base must be securely mounted and capable of reliably supporting at least 35 lbs.  See page 6 of owner’s manual for

support requirements.  Consult a qualified electrician if in doubt.

4.   The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

5.   Follow the recommended instructions for the proper method of wiring your ceiling fan.  If you do not have adequate electrical

knowledge or experience, have your fan installed by licensed electrician.

6.   Suitable for use with solid-state speed controls.

WARNING:

  TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH A GENERAL USE ISOLATING WALL 

CONTROL/SWITCH.

WARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 

damage.

WARNING:

  To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, 

balancing the blades, or cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. If the intentional radiator can be classified as a Class B digital device or a PC 

peripheral, then shall include the following or equivalent:

Note:

 This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the

instructions, may cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna. 

- Increase the separation between the equipment and the receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help. 

Note:

 For a Class A digital device, statements of 15. 105(a) must be included when appropriate for the device in question.

6.   The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to 

      ensure that they do not play with the appliance. 

8.   For supply connections, if the conductor of a fan is identified as a grounded conductor, then it should be connected to a grounded

conductor power supply. If the conductor of a fan is identified as an ungrounded conductor, then it should be connected to an ungrounded

conductor power supply. If the conductor of a fan is identified for equipment grounding, then it should be connected to an 

equipment grounding conductor.

7.   This fan is to be used in dry location only.

WARNING:  

Do not operate this fan with a variable (Rheostat) wall controller or dimmer switch. Doing so could result in damage to the 

  

ceiling fan's remote control unit.   

Summary of Contents for EMBRACE FPS7955B

Page 1: ...ESE INSTRUCTIONS Questions problems missing parts Before returning to your retailer call our customer service department at 1 888 567 2055 8 a m 5 p m EST Monday Friday FPS7955B Net Weight 21 08 lbs 9...

Page 2: ...s while the fan is operating 5 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions 1 To avoid possible shock be sure electricity is turned off...

Page 3: ...w to Assemble the Ceiling Fan Blade How to Assemble the Light Kit or Cap 10 How to Operate Your Ceiling Fan 12 9 How to Assemble Your Ceiling Fan 9 Maintenance 13 Blade Cleaning 13 How to Install Your...

Page 4: ...bly Blade Set 44 FPS7981B Blade Set 52 FPS7955B Blade Holder Set Four wire connectors Four Wire Connectors WARNING Do not install or use fan if any part is damaged or missing This product is designed...

Page 5: ...in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional...

Page 6: ...h brace Figure 3 Paired with a deep box this hanger is meant to span between two joists and takes the place of wooden blocking To avoid fire or shock follow all wiring instructions carefully Any elect...

Page 7: ...ucture Figure 2 You will first drill a pilot hole into the building structure to prevent splitting or cracking 2 The ceiling support cable need to through the center hole of ceiling bracket when mount...

Page 8: ...ON DIP 1 2 3 4 5 8 5 To set the code on receiver unit slide dip switches to the same positions as set on the remote Figure 4 NOTE The remote unit has 32 different code combinations To prevent possible...

Page 9: ...ssemble the Ceiling Fan Blades x 9 x 9 FLAT WASHER SERRATED HEAD SCREWS HARDWARE USED 1 Position the blade over the blade holder with threaded posts showing Make sure the bottom edge of the blade is f...

Page 10: ...e risk of electric shock disconnect the electrical supply circult to the fan before installing light kit CAUTION Blade Holder Motor Assembly Figure 2 Screws 2 per assembly 1 Remove one of the three sc...

Page 11: ...ING Figure 4 Light Plate Assembly Light Plate Assembly Glass 3 Option A for use with light kit Securely attach 9 pin connector from motor assembly to wiring harness socket within light kit assembly As...

Page 12: ...attery included in hand held remote transmitter with fan power off Then follow the remote code setting process If not used for long periods of time remove battery toprevent damage to transmitter Store...

Page 13: ...commended A feather duster will work best Avoid using water cleansers or harsh rags which can warp and ruin the blades CAUTION Do not use solvents when cleaning your ceiling fan It could damage the mo...

Page 14: ...ousing are snug not over tight 3 Check to make sure the screws which attach the fan blade to the blade arm with holder are tight 4 Check to make sure wire connectors in motor housing are not rattling...

Page 15: ...e Holder Set 4 5 6 7 8 9 11 10 Blade Set 44 FPS7981B Blade Set 52 FPS7955B Hand Held Remote Rreviece Unit Hardware Bags Containing Wire Connectors 4 3 16 24 Serrated Head Screws with Flat Washer 10 g...

Page 16: ...16 NOTE FPS7955B Figure 1 5 4 6 7 7a 7b 1 2 3 Exploded View Illustration 11 11 11 11 10 9 8...

Page 17: ...17 NOTE FPS7981B Figure 1 5 4 6 7 7a 7b 1 2 3 Exploded View Illustration 11 11 11 11 10 9 8...

Page 18: ...Copyright 2019 Fanimation 2019 02 V 01 10983 Bennett Parkway Zionsville IN 46077 Phone 888 567 2055 Outside U S 317 733 4113 FANIMATION COM FAX 866 482 5215...

Page 19: ...ION COM LEA Y GUARDE ESTAS INSTRUCCIONES FPS7955B Peso neto 9 56 kgs 21 08 lbs FPS7981B Peso neto 8 44 kgs 18 61 lbs Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro De...

Page 20: ...erencias perjudiciales y 2 este equipo tolerar cualquier interferencia recibida incluidas las interferencias que puedan provocar un funcionamiento no deseado Si el radiador intencional puede ser clasi...

Page 21: ...8 En ning n caso se podr devolver un ventilador sin previa autorizaci n por parte de Fanimation Las devoluciones autorizadas deber n ir acompa adas del recibo de venta y deber n enviarse a Fanimation...

Page 22: ...o para ser usado s lo con las piezas suministradas o los accesorios indicados porFanimationespec ficamenteparaelmismo Lasustituci n de piezas o accesorios no designados por Fanimation para usarse con...

Page 23: ...tinuaci nlepresentamosalgunassugerencias para asegurar un rendimiento eficiente del producto Selecci n del lugar de montaje adecuado Los ventiladores de techo se deben instalar en el centro de la habi...

Page 24: ...NCIA A fin de evitar incendios o descargas el ctricas siga con cuidado todas las instrucciones de instalaci n el ctrica Cualquier trabajo el ctrico que no se describa en estas instrucciones deber ser...

Page 25: ...och de fa on ce que ses pales soient au moins 7 pieds Figure 1 AVERTISSEMENT AVERTISSEMENT Para evitar una posible descarga el ctrica aseg rese de cortar la alimentaci n el ctrica de la caja de fusibl...

Page 26: ...or Figura 4 NOTA Los ajustes de f bricas vienen con todos los interruptores hacia arriba No utilice esta posici n NOTA El mando a distancia incluido en este ventilador tiene 32 combinaciones diferente...

Page 27: ...jeci n de las palas Figura 1 20 PRECAUCI N Figura 1 x 9 x 9 Arandela de Plana Aditamentos utilizados Tornillo de cabe za dentada de 3 16 24 3 cada uno por aspa Aspas Soporte de aspas Tornillos de Figu...

Page 28: ...tale la ensamble de la placa de iluminaci n en el soporte utilizando las dos el soporte utilizando las dos ranuras principales Vuelva a colocar el tercer tornillo y asegure apriete Figura 1 3 Fije fir...

Page 29: ...Ensamble del carcasa del interruptor Unidad de LED Figura 5 Figura 6 Figura 7 Unidad de Motor Tapa de acero Ensamble de la placa de iluminaci n 6 Fije firmemente el conector de 9 pasadores de la unid...

Page 30: ...ente incluyendo la toma de tierra y que no se visualizan ning n cable pelado en los conectores de cables con la excepci n del cable de toma de tierra No utilice el ventilador hasta que las palas est n...

Page 31: ...om tico Pulse y tanto el ventilador y la iluminaci n se apagar n tras 1 hora Pulse y tanto el ventilador y la iluminaci n se apagar n tras 3 hora Pulse y tanto el ventilador y la iluminaci n se apagar...

Page 32: ...ren agentes abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado C mo limpiar las palas de su ventilador de techo Evite usar agua productos de limpieza o trapos speros que...

Page 33: ...en la caja del interruptor no produzcan ruido al rozar unos con otros o al rozar la pared interior de la caja del interruptor 4 Algunos motores de ventilador son sensibles a las se ales de los control...

Page 34: ...D FPS7955B Pieza N FPS7981B Pieza N AMA7955B AP796701 P796703 AP796702 AP796752 AP796705B AP798103 AP798104 AP796706 TR500 RCCA05004001 HDWFPS7981B Cable de seguridad y Bolsa 30 Unidad del motor del v...

Page 35: ...Figura 1 Modelo N FPS7955B Ilustraci n del despiece NOTA 16 5 4 6 7 7a 7b 1 2 3 11 11 11 11 10 9 8...

Page 36: ...Figura 1 Modelo N FPS7981B Ilustraci n del despiece NOTA 17 5 4 6 7 7a 7b 1 2 3 11 11 11 11 10 9 8...

Page 37: ...19 Fanimation 2019 02 V 01 Visite nuestro sitio Web en www fanimation com 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 3...

Reviews: