How to Hang and Wire Your Ceiling Fan
You will first drill 4.76 m pilot holes into the plywood
base or supporting member to prevent splitting or cracking.
Mount the Pulley Assembly on the ceiling with 4 lag bolts
and flat washers (Figure 1a).
Drill 4.76 m pilot hole located approximately as shown in
Figure 1a & 1b for lag “J” hook. Screw lag hook into ceiling.
Hang motor assembly on lag hook for ease of wiring
fan motor (Figure 1b).
Floor
Ceiling
No
less than
2.3 m
4.27 m max - motor to head
1.22 m min
(4.11 m max - head to head)
Figure 1a
Figure 2
5 cm Lag Bolt
& Flat Washer
(4 places)
5 cm Lag
Bolt
& Flat
Washer
(4 places)
Outlet Box Flush
to Finished
Ceiling
Plywood ( 2 cm thick min.)
Backing Secured to
Structural Member
Figure 1b
CAUTION
Do not connect fan blades until the fan is completely
installed. Hanging fan with blades connected may result
in damage to the fan blades.
INSTALLATION NOTE
WARNING
Do not install or use fan if any part is damaged or
missing. This product is designed to use only those
parts supplied with this product and/or any accessories
designated specifically for use with this product by
Fanimation. Substitution of parts or accessories not
designated for use with this product by Fanimation could
result in personal injury or property damage. Contact
your retail store for missing or damaged parts.
INSTALLATION NOTE
e
v
a
h
r
o
t
o
m
e
h
t
d
n
a
n
a
f
h
c
a
e
t
a
h
t
d
e
d
n
e
m
m
o
c
e
r
s
i
tI
2 cm plywood backing secured to a structural member
for adequate support (Figure 1). The motor unit will not
operate more than 4 pulley/blade assemblies.
INSTALLATION NOTE
Motor assembly can be mounted at either end of Pulley
assembly or in the middle.
The fan must be hung with at least 2.3 m of clearance
from floor to blade. The maximum overall (belt) length
between motor & pulley is 4.27 m and the minimum is
1.22 m. (Figure 2) For two-pulley assembly installation:
The maximum overall distance between two pulley
assemblies is 4.11 m and the minimum is 1.52 m.