28
WARNING : Before proceeding to the electrical connections, carefully read the safety instructions in
this manual. Before any electrical connections, switch off all power and restart only when the instal-
lation is completed. Electrical connections must be made in accordance with current regulations and
by a qualified electrician.
Once the receiver is installed in the hanger bracket, make the electrical connections below (see diagram on
next page) :
1/ CONNECTIONS FROM CEILING FAN TO RECEIVER
- Connect the connector of the ceiling fan (3 wires : pink / grey / red) to the receiver.
- Connect the connector of the ceiling fan (3 wires : yellow / black / white) to the one of the receiver. If your
ceiling fan is not equipped of a light, ignore this last connection, do not connect that connector to the receiver.
2/ CONNECTIONS FROM RECEIVER TO HANGER BRACKET
- Connect the connector of the hanger bracket (3 wires : brown or black / blue / yellow and green) to the re-
ceiver.
The brown or black wire corresponds to the phase (Line), the blue wire corresponds to the neutral, the yellow
and green wire corresponds to the ground (Earth).
3/ CONNECTIONS FROM HANGER BRACKET TO AC CEILING POWER
By using the connecting terminals provided on the hanger bracket :
- Connect the phase of the ceiling to the phase of the hanger bracket in the domino L (LINE : black or brown
wire of the hanger bracket).
- Connect the neutral of the ceiling with the neutral of the hanger bracket in the domino N (NEUTRAL : blue
wire of the hanger bracket).
4/ GROUNDING
- Connect the ground wire of the ceiling to the ground wire of the hanger bracket in the domino E (EARTH :
11. ELECTRICAL CONNECTIONS
Receiver
Receiver
Once your ceiling fan is installed in the hanger bracket, slide the receiver into the hanger bracket (above the
hanger ball).
10. INSTALL THE RECEIVER IN THE CEILING HANGER BRACKET