Page: 8/16
2
)
Elongate the heat pipe and snap the flat end of the heat pipe joints into the elliptical hole
of the window sealing plate assembly (as shown in Figure 5 and Figure 6) .
Notes: 1. the flat end of the heat pipe joints must be snapped into place.
2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the
ventilation of the heat pipe unobstructed.
Figure5 Figure 6
Important Notice
The length of the exhaust hose shall be 280~1,500mm, and this length is based on the
specifications of the air conditioning. Do not use extension tubes or replace it with other different
hoses, or this may cause a malfunction. Exhaust must be unobstructed; otherwise it may cause
overheating.