F&U PA-91 Instructions For Use Manual Download Page 4

1.POWER KEY      

Press to turn unit "ON" or "OFF".

 

2. FUNCTION       

Press this key to select refrigeration, heat or dehumidification.

 

or

 

cooling

.

 

3. TEMPERATURE REGULATION KEY (UP)   

  During cooling function

This key raises the preset temperature by 1

  each time it is   

pressed to a maximum of 30

℃。

 

During heating function

This key raises the preset temperature by 1

  each time it is   

pressed to a maximum of 25

 

4. TEMPERATURE REGULATION KEY (DOWN)

 

  During cooling function

This key lowers the preset temperature by 1

each time it is   

pressed to a minimum of 17

 . 

During heating function

This key lowers the preset temperature by 1

  each time it is   

pressed to a minimum of 15

.

 

5. L.E.D. DISPLAY

         

  Indicates the temperature or the time setting. After any time set the display will return to the 

preset temperature automatically. 

6. SPEED      

Press to select either LOW, MEDIUM, HIGH or AUTO fan speed. 

                                  If "AUTO" is selected(During cooling function),”HIGH” or "MEDIUM" or 

“LOW" will be selected automatically according to the difference between 

setting temperature and room temperature. 

 

 

 

Note: In heating function and dehumidifying function, the wind-speed setting is inefficacy because 

the unit has setted high-speed(heating) and low-speed(dehumidifying).

7. PROGRAMMABLE

 

TIMER

     

Programmable timer ON/OFF key. 

TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over. 

1. Press the "TIMER" key at stand-by status to set the time desired. 

2. Once the set hour has come to an end, the unit will turn on automatically. 

3. Press the "POWER" key before time out, the setting time will be canceled and the unit will 

turn on. 

TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting time is 

over. 

1). Press the "TIMER" key at stand-by status to set the time desired. 

2). Once the set hour has come to an end, the unit will turn off automatically. 

3). Press the "POWER" key before the time out, the setting time will be canceled and the 

unit will turn off. 

 

8.SLEEP CONTROL

 

FUNCTION

       

When setting the "sleep comfort" mode please ensure that you then set the number of 

hours required and press the timer button till those hours are indicated on the L.E.D 

display. After setting the hours the L.E.D. display will automatically return to the current 

pre-set temperature. To increase this setting "up" press button indicating and for each 

press, the temperature will be increased by 2

. Likewise to set for a lower temperature 

press button indicating and for each press the temperature will be decreased by 2

 

 

During the course of this cycle, to ensure maximum sleep comfort. the micro-processor 

memory will raise the pre-set temperature 1

  each half hour to a maximum of 4

over 

two hours and then maintain that temperature for the balance of the time set. 

 

The portable air conditioner is fitted with a 3 minute compressor delay protection circuit 

which simply means that the compressor requires 3.5 minutes to start. From either being 

switched on, or when changing from “dehumidify” to any air conditioning cycle chosen. 

Summary of Contents for PA-91

Page 1: ...t should not be operated in heating function an indoor ambient temperature above 7 or lower23 Clean air filter periodically to enjoy the most efficient cooling 7 When the unit is shut off please wait at least 3 5 minutes before restarting this is to prevent the compressor from being damaged 8 This unit needs at least 7 Amps of electricity to have its compressor operational To avoid the household e...

Page 2: ...r their safety Children should be supervised to ensure that they do not play with the appliance CONGRATULATIONS ON YOUR SELECTION OF A QUALITY PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER Your Air Conditioner has been designed and manufactured to the highest standards of modern engineering Its many features not only include remote control Operation that lets you control all functions with eas...

Page 3: ...lift until it slides out of the foam base 5 Disconnect the tie in inside the exhaust tube and take out the exhaust tube 6 Install the exhaust tube on the unit before operating the unit CONTENTS 1 Air control unit 2 1 remote control unit NAME OF THE PARTS 1 Control panel 2 Remote receiver 3 Adjustable air vent 4 Joint tube 5 Exhaust tube 6 Up drain pipe 7 Cool inlet 8 Cool Air filter 9 Hot inlet 10...

Page 4: ...et the time desired 2 Once the set hour has come to an end the unit will turn on automatically 3 Press the POWER key before time out the setting time will be canceled and the unit will turn on TIMER OFF The timer off is used to turn off the unit automatically after the setting time is over 1 Press the TIMER key at stand by status to set the time desired 2 Once the set hour has come to an end the u...

Page 5: ...sation and flow out through the exhaust hose automatically 1 When the unit is in the cooling or heating function it does not need to install the drain hose Please make sure that the rubber cap is locked on drain hose when the unit is running 2 When operating heating function in order to improve the heating effect or prevent low temperature lower than 17 water full phenomenon will happen And then w...

Page 6: ...NET Wipe with a damp cloth and polish with a soft cloth To remove the air filter please follows the arrow direction and push the filter lightly and then take out the filter for cleaning POWER SUPPLY 1 Confirm the correct power 2 Insert the plug into the outlet firmly In case of dangerous leak prevent the AC cord from scarring 3 Don t pull power wire by force because it will cause damage to power w...

Page 7: ...it s performance dramatically Do not place the unit in direct sunlight as this may cause the unit to overheat and turn off EXHAUST TUBE INSTALL 1 Circumrotate the wind pipe according to the direction as the arrowhead indicates and then the wind pipe can be took out from the unit 2 Circumrotate the wind pipe according to the direction as the arrowhead indicates and then make it connect with the uni...

Page 8: ...om your household waste Please dispose of this equipment at your local community waste collection recycling centre In the European Union there are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY This product complies with the requirements of the directives EMC Directive 2004 108 EC Low Voltage D...

Reviews: