Please read the instructions carefully before installation.

»

The device should be installed and operated by qualified per-

sonnel who are familiar with its design, operation, and asso-

ciated risks.

»

Do not install a meter that is damaged or incomplete.

»

The user is responsible for proper grounding of the system, 

proper selection, installation, and efficiency of other devices 

connected to the meter, including safety devices such as over-

current, residual current and overvoltage circuit breakers.

»

Before connecting the power supply, make sure that all cables 

are connected correctly.

»

It is essential to observe the operating conditions of the meter 

(supply voltage, humidity, temperature).

»

To avoid electric shock or damage to the meter, turn off the 

power supply whenever the connection is changed.

»

Do not make any changes to the unit yourself. Doing so can re-

sult in damage to or improper operation of the device, which 

in turn can pose a threat to people operating it. In such cases, 

the manufacturer is not responsible for the resulting events 

and may refuse the provided warranty in the event of a com-

plaint.

»

Do not tighten the terminals without the wire inserted. This 

may damage the lift mechanism of the terminal or the plastic 

cover of this terminal.

General work safety conditions

Summary of Contents for WZE-1

Page 1: ...s value is indicated on a segmented LCD Decimal digits indicate the hundredth of kWh 0 01 kWh 10 Wh Compliance Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to the Law on Waste electro coming from households free of...

Page 2: ...onal device is required for the correct operation of the meter The meter has the option of sealing the input and output termi nals preventing the meter from being bypassed The meter is marked with an individual factory number to enable its unambiguous identification The marking is indelible laser engraving Pulse output Sealing Number of the meter ...

Page 3: ... 3 Description of the front of the device ...

Page 4: ... 4 Dimensions ...

Page 5: ... 5 1 phase wire power supply 3 phase wire output 4 6 neutral wire 20 pulse output 21 pulse output Connection diagram ...

Page 6: ...receiver is not required reference voltage 230 V AC 50 Hz base current 5 A maximum current 45 A minimum detection current 0 02 A accuracy class EN50470 1 3 B energy consumption of the meter 8 VA 0 4 W rang of indications 0 99999 99 kWh meter constant 1 Wh imp 1000 imp kWh readout indication LED red SO SO pulse output open collector SO SO connection voltage 27 V DC SO SO connection current 27 mA SO...

Page 7: ...r contact us directly F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found at www fif com pl from the product subpage T...

Page 8: ...that all cables are connected correctly It is essential to observe the operating conditions of the meter supply voltage humidity temperature To avoid electric shock or damage to the meter turn off the power supply whenever the connection is changed Do not make any changes to the unit yourself Doing so can re sult in damage to or improper operation of the device which in turn can pose a threat to p...

Reviews: