Time of activation can be programmed upon the assumed time 

of roller blind operation or by activating the roller blind for the 

test run.

Scheduling for the specified time

1. Press and hold (for approx. 4 s) the 

����

 button until the 

green U LED will begin to flash slowly. The controller is now 

ready for programming.

2. Short press 

����

 button – the controller starts to measure out 

the activation time, which is indicated by rapid flashing of U 

LEDs.

3. After the time has been measured out, press the 

����

 button 

again. The controller will save the elapsed time in non-volatile 

memory and then exit the programming mode, which is indi-

cated by the constant U LED light.

Test run

1. Place the blind in the outmost top or bottom position.

2. Press and hold (for approx. 4s) the 

����

 button until the green 

U LED will begin to flash slowly. The controller is now ready for 

programming.

3. Short press the local control 

��

 or 

����

 button (in the oppo-

site direction to the current position of the roller blind). The 

controller starts the motor and begins to measure out the 

time.

4. After the time has been measured out, press any of the local 

control buttons. The roller blind motor will stop and the con-

troller will save the elapsed time in "non-volatile" memory and 

then exit the programming mode.

Scheduling time of activation

Summary of Contents for STR-4D

Page 1: ...that allows to fully lift or lower the roller blind Roller blind can be stopped on the user selected level incomple te opening or closing of the roller blind Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Do not dispose of this device in the trash along with other waste According...

Page 2: ...eady in motion causes the roller blind to stop Long press 0 5 s switches on the roller blind for as long as the button is pressed Each time you press the button the roller blind will move in the direction opposite to the previous one Two local buttons Each direction of movement has its own local button Short press 0 5 s switches on the roller blind to move in a given direction for the programmed p...

Page 3: ...ove only in the de sired direction Roller blind will stop only after a preset time or by pressing any of the local control buttons If during the execution of one center control command another one is issued with the instruction to move in the opposite direc tion the roller blind will stop at first and after 1 5 s will then start to move in the opposite direction Time of roller blind activation can...

Page 4: ...en preparing the installation powered with 12 24 V voltage it is necessary to provide a power source with sufficient current capacity to supply all receivers Too small power supply may lead to improper operation of motors and roller shutter controllers Additionally vol tage drops on cables mainly power cables should be taken into account and if necessary the diameter of the cables should be increa...

Page 5: ...ime in non volatile memory and then exit the programming mode which is indi cated by the constant U LED light Test run 1 Place the blind in the outmost top or bottom position 2 Press and hold for approx 4s the button until the green U LED will begin to flash slowly The controller is now ready for programming 3 Short press the local control or button in the oppo site direction to the current positi...

Page 6: ...xit the learning mode The controller is designed to measure time span shorter than 15 min Attempting to set the controller for longer span will result in exit from the learning mode The controller learning mode can be started only when the roller blind motor is turned off Operation with factory settings activation time set to 30 seconds is indicated in standby mode by short 0 1 s blinking of U LED...

Page 7: ...tton 1 3 power supply 10 27 V DC 4 central control direction 6 central control direction 7 local control direction 9 local control direction 10 motor power supply terminal A 12 motor power supply terminal B Connection diagram ...

Page 8: ... local buttons 1 3 power supply 10 27 V DC 4 central control direction 6 central control direction 7 local control direction 9 local control direction 10 motor power supply terminal A 12 motor power supply terminal B ...

Page 9: ... products are covered by a 24 month warranty from the date of purchase The warranty is only valid with proof of purchase Contact your dealer or contact us directly F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity al...

Page 10: ......