- 5 -
Local buttons
Short press of a button activates the roller-blind in the selected direction of movement.
Subsequent press during the roller-blind movement causes it to stop.
Long press of a button (for longer than 5 seconds) activates the programming mode of the
passage time of the roller-blind.
Passage time programming
The default time of roller-blind passage is 30 seconds.
To change this time you need to:
unroll the roller blind to the maximum by pressing the down direction button;
when the roller-blind stops, release the down direction button and then press and hold the
up direction button of the roller-blind;
after 5 seconds the roller-blind will start to roll up, and when it stops in the utmost upper
position immediately release the up direction button;
time of the roller-blind passage can be adjusted in the range of 5÷120 seconds.
Remote buttons
The FW-RC4, FW-RC10 transmitter operate on the principle of a bistable switch:
one press of a button activates the roller-blind in a selected direction of movement,
the second press of a button during the movement of the roller-blind causes it to stop.
The FW-RC5 transmitter also has separate inputs ON (always raise the roller-blind)
and OFF (always lower the roller-blind).
Due to the nature of transmission and retransmission do not use the same button in
transmitter more often than every 2 seconds. Switching of the receiver may be carried
out with a short delay.
We do not recommend the use of remote bistable transmitters to control
a group of receivers due to the possibility of desynchronization of the activation state
(especially when operating on larger distances and/or simultaneous use of local but-
tons on the receivers).
Activation of the thermal protection is indicated by a steady pulsing of communication
LED, switching off of the output circuit and the lack of its reactivation possibility. After
lowering the temperature to a safe value the output circuit will remain switched off
until restarted.