power supply 

18÷24 V AC

 

21÷27 V DC

maximum load current (AC-1) 

5 A*

frequency of microwaves radiation 

5.8 GHz

radiation power 

10 mW

detection field 

360°

detection radius (adjustable)

for h= 2.5 m 

1÷10 m

activation threshold (adjustable) 

2÷2000 lx

switching time (adjustable) 

5 s÷12 min.

activation delay 

1 s

power consumption 

0.9 W

terminal 

1.0 mm² screw terminals

tightening torque 

0.25 Nm

working temperature 

-25÷50°C

dimensions 

ø103, H= 44 mm

mounting surface

mounting height 

2÷6 m

ingress protection 

IP20