- 11 -

The F&F products are covered by a warranty of the 24 months  

from the date of purchase.  Effective only with proof of purchase. 

Contact your dealer or directly with us.

F&F Filipowski L.P. declares that the device is in conformity 

with the essential requirements of The Low Voltage Directive 

(LVD)  2014/35/EU and the Electromagnetic Compatibility (EMC) 

Directive 2014/30/UE.

The CE Declaration of Conformity, along with the references to 

the standards in relation to which conformity is declared, can be 

found at www.fif.com.pl on the product page.

Warranty

CE declaration

E230719

Summary of Contents for DRL-60-12

Page 1: ...or This solution is perfect for switching on lighting circuits for exam ple on open stairs where it is important that the sensor detects presence only on the stairs and ignores everything that happens...

Page 2: ...25D staircase li ghting timers Compact size can be mounted in a 60 mm box LED indicating the operating status of the sensor Thermal protection against exceeding the acceptable tempe rature inside the...

Page 3: ...ncorrect operation of the distance and light intensity measurement system 3 Do not mount sensors opposite each other or mirrors as this can lead to unwanted sensor excitation 4 Prepare a hole for the...

Page 4: ...load of the cable 8 Use the dials to set the operating parameters of the detector detection range level of brightness below which switching will occur and switching time of the light 9 Slide the dete...

Page 5: ...ensor power supply 0 V OUT Lighting control output The DRL 60 12 is equipped with an open collector type output This means that the lighting to be controlled must be connected between the of the power...

Page 6: ...ction area 3 TIME 0 10 min Lighting support time The light will switch on when presence is detected in the detection area the countdown time will start when there is no more obstacle in the detection...

Page 7: ...control a load greater than 4 A the LED AMP 1P signal amplifiers mounting in an installation box 60 or LED AMP 1D mounting on a DIN rail should be used An example connection diagram can be found on th...

Page 8: ...8 Connection of the AS 225 cascade controllers...

Page 9: ...the detection area An obstacle in the detection area has been detected The light was not switched on because the brightness level was too high An obstacle in the detection area has been detected The l...

Page 10: ...power supply 9 27 V DC maximum load current 4 A detection range adjustable 0 1 2 0 m brightness level adjustable 2 500 lx switch on time adjustable 0 10 min detection sensor ToF laser sensor wave len...

Page 11: ...P declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaratio...