F&F DRL-60-12 Manual Download Page 1

- 1 -

DRL-60-12

Laser distance sensor,

12 V

The DRL-60-12 is a laser sensor designed to control lighting, 

especially in corridors and staircases. 

The principle of operation is to emit a light beam and measu-

re the delay of returning light as a result of reflection from an 

obstacle. On this basis, it is possible to precisely determine the 

distance to the obstacle, which is then compared with the set 

detection range.

The condition for switching on the light is the presence of an 

obstacle at a distance smaller than the set detection range and a 

brightness level below the value set on the sensor. 

This solution is perfect for switching on lighting circuits for exam-

ple on open stairs, where it is important that the sensor detects 

presence only on the stairs and ignores everything that happens 

outside.

Purpose

F&F Filipowski L.P.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste! 

According to the Law on Waste, electro coming from households free of charge and can 

give any amount to up to that end point of collec� on, as well as to store the occasion of 

the purchase of new equipment (in accordance with the principle of old-for-new, regard-

less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for DRL-60-12

Page 1: ...or This solution is perfect for switching on lighting circuits for exam ple on open stairs where it is important that the sensor detects presence only on the stairs and ignores everything that happens...

Page 2: ...25D staircase li ghting timers Compact size can be mounted in a 60 mm box LED indicating the operating status of the sensor Thermal protection against exceeding the acceptable tempe rature inside the...

Page 3: ...ncorrect operation of the distance and light intensity measurement system 3 Do not mount sensors opposite each other or mirrors as this can lead to unwanted sensor excitation 4 Prepare a hole for the...

Page 4: ...load of the cable 8 Use the dials to set the operating parameters of the detector detection range level of brightness below which switching will occur and switching time of the light 9 Slide the dete...

Page 5: ...ensor power supply 0 V OUT Lighting control output The DRL 60 12 is equipped with an open collector type output This means that the lighting to be controlled must be connected between the of the power...

Page 6: ...ction area 3 TIME 0 10 min Lighting support time The light will switch on when presence is detected in the detection area the countdown time will start when there is no more obstacle in the detection...

Page 7: ...control a load greater than 4 A the LED AMP 1P signal amplifiers mounting in an installation box 60 or LED AMP 1D mounting on a DIN rail should be used An example connection diagram can be found on th...

Page 8: ...8 Connection of the AS 225 cascade controllers...

Page 9: ...the detection area An obstacle in the detection area has been detected The light was not switched on because the brightness level was too high An obstacle in the detection area has been detected The l...

Page 10: ...power supply 9 27 V DC maximum load current 4 A detection range adjustable 0 1 2 0 m brightness level adjustable 2 500 lx switch on time adjustable 0 10 min detection sensor ToF laser sensor wave len...