Technical data

power supply

230V AC

current load

<3A

twilight activation threshold

3÷2000Lx

motion of detection

0.6

÷

1.5m/sec

switch-off time

10

s

ec 3sec

 ÷ 

7

min

.

±

2min.

vertical detection field

160

°

maximum radius detection (T<24

°

C)

9m

sensor height installation

h=1.0

÷

1.8m

power consumption

0.5W

terminal

1.0mm

²

 screw terminals

working temperature

-10÷40°C

dimensions

external

80×80×62mm

groove

Ø

=60mm, depth=32mm

mounting hole

Ø

=60mm

screw spacing

58mm

mounting

two screws to substrate 

in flush mounted Ø60

protection level

IP20

±

500W

100W

500W

incandescent

fluorescent

energy-saving

halogen

LED

100W

100W

Table of power

D161014

Wiring diagram

- 5 -

- 7 -

- 6 -

- 8 -

(N)

L

L

N

(N)

L

L

N

DR-03

DR-03

80 mm

Dimensions

62 mm

32 mm

48 mm

80 mm

Note!

mounting handle

mounting hole

mounting screw

1)

2)

3)

4)

open cover
pry 2 hooks

Unmounting/mounting of device

1) Do not mount 

near the outlet of the air conditioner

 or other 

heat sources.

2) Do not mount in direct sunlight area.
3) D

o not mount near the moving objects

.

4) Do not mount near the light source (min. distance 60 cm).

The above data are indicative and will heavily depend on the design of a specific receiver 
(that is especially important for LED bulbs, energy-saving lamps, electronic transformers and 
pulse power supply units), switching frequency and operating conditions.
For more information visit: www.fif.com.pl.