- 3 -
- 4 -
- 1 -
- 2 -
D141223/150116
Specifications
Wiring diagram
BISTABLE RELAY
with switch off timer
BIS-410i
power supply
V AC
contact / load current
current control pulse L
< mA
response delay
0.1÷0.2s
off time - adjustable
1÷15min.
supply signalling
green LED
power consumption
standby
0.
W
on
0.6W
working temperature
-
÷50°C
terminal
screw terminals
tightening torque
0.4Nm
mounting
in the Ø60 flush-mounted box
ingress protection
I 20
100÷265
AC-1
1NO / <16A
(160A/20ms)
5
15
25
dimensions
Ø
54 (□48×43mm), h= 20mm
P
2.5mm
²
2000W
1000W
1250W
incandescent
fluorescent
energy-saving
halogen
LED
500W
250W
Power table
The above data are indicative and will depend to a large extent on
the design of a specific receiver (especially for LED bulbs, energy
saving lamps, electronic transformers and pulse power supplies),
switching frequency and working conditions.
For more information visit: www.fif.com.pl.
Purpose
Electronic bistable impulse relay allows switching of lighting or
other equipment from several different points of using the control
buttons are connected in parallel.
L
N
N
L
BIS
Functioning
L
N
2
3
5
L
1
N
L
6
4
N
PWR
L
N
The receiver is followed by current pulse triggered by pressing any
(bell) connected to the relay. Turning off the receiver will be the
next pulse or automatically turn off after a preset time. Longer
duration (minimum 2 seconds) pressing the relay instantaneous
permanently. It will cut out after a momentary button is pressed
again (or after a power failure).
t
>t
>2s
t
U
t
t
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: [email protected]
Do not dispose of this device to a garbage bin with other unsorted waste!
In accordance with the Waste Electrical and Electronic Equipment Act
any household electro-waste can be turned in free of charge and in any
quantity to a collection point established for this purpose, as well as to the
store in the event of purchasing new equipment (as per the old for new rule,
regardless of brand). Electro-waste thrown in the garbage bin or abandoned
in the
bosom of nature pose a threat to the environment and human health.
WARRANTY.
The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealeror directly with us. More
information how to make a compliant can
be found on the website:
www.fif.com.pl/reklamacje
Assembly
1. Disconnect the power supply.
2. The relay mounted in flush-mounted box.
3. Connect the power supply to a group of PWR: L phase wire
to terminal 5 or 6. The N neutral to terminal 3 or 4.
4. Parallel momentary switches connected to terminal 1 and
the L phase conductor.
5. Powered receiver connected in series to terminal 2 and
the N neutral conductor.
6. Potentiometer to set the switch-off time.
Note!
BIS-410 can be used with illuminated buttons.
5
9 0 8 3 1 2
5 9 8 3 1 2
Relay version "i" is to pin adapted to cooperate with the receivers
with high starting current, such as LED fluorescent lamps,
ESL fluorescent lamps, electronic transformers, discharge lamps,
etc.