background image

- 3 -

- 4 -

- 1 -

- 2 -

D141223/150116

Specifications

Wiring diagram

BISTABLE RELAY

with switch off timer

BIS-410i

power supply

V AC

contact / load current
current control pulse L

< mA

response delay

0.1÷0.2s

off time - adjustable

1÷15min.

supply signalling

green LED

power consumption
      standby

0.

W

      on

0.6W

working temperature

-

÷50°C

terminal

screw terminals

tightening torque

0.4Nm

mounting

in the Ø60 flush-mounted box

ingress protection

I 20

100÷265

 AC-1

1NO / <16A 

(160A/20ms)

 

5

15

25

dimensions

Ø

54 (□48×43mm), h= 20mm

P

2.5mm  

²

2000W

1000W

1250W

incandescent

fluorescent

energy-saving

halogen

LED

500W

250W

Power table

The above data are indicative and will depend to a large extent on 
the design of a specific receiver (especially for LED bulbs, energy 
saving lamps, electronic transformers and pulse power supplies), 
switching frequency and working conditions.
For more information visit: www.fif.com.pl.

Purpose

Electronic  bistable  impulse  relay  allows  switching  of  lighting  or 
other equipment from several different points of using the control 
buttons are connected in parallel.

L

N

N

L

BIS

Functioning

L

N

2

3

5

L

1

N

L

6

4

N

PWR

L

N

The receiver is followed by current pulse triggered by pressing any 
(bell) connected to the relay. Turning off the receiver will be the 
next pulse or automatically turn off after a preset time. Longer 
duration (minimum 2 seconds) pressing the relay instantaneous 
permanently. It will cut out after a momentary button is pressed 
again (or after a power failure).

t

>t

>2s

t

U

t

t

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

phone/fax: (+48 42) 215 23 83 / 227 09 71    POLAND

http://www.fif.com.pl   e-mail: [email protected]

Do not dispose of this device to a garbage bin with other unsorted waste! 

In  accordance  with  the  Waste  Electrical  and  Electronic  Equipment  Act 
any  household  electro-waste    can  be  turned  in  free  of  charge  and  in  any 
quantity to a collection point established for this purpose, as well as to the 
store in the event of purchasing new equipment (as per the old for new rule, 
regardless of brand). Electro-waste thrown in the garbage bin or abandoned 
in the

 

bosom of nature pose a threat to the environment and human health.

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with  proof  of  purchase.  Contact  your 
dealeror  directly  with  us.  More 
information how to make a compliant can 
be found on the website:
www.fif.com.pl/reklamacje

Assembly

1. Disconnect the power supply.
2. The relay mounted in flush-mounted box.
3.  Connect  the  power  supply  to  a  group  of  PWR:  L  phase  wire 

to terminal 5 or 6. The N neutral to terminal 3 or 4.

4.  Parallel  momentary  switches  connected  to  terminal  1  and 

the L phase conductor.

5.  Powered  receiver  connected  in  series  to  terminal  2  and 

the N neutral conductor.

6. Potentiometer to set the switch-off time.

Note!

BIS-410 can be used with illuminated buttons.

5

9 0 8 3 1 2

5 9 8 3 1 2

Relay version "i" is to pin adapted to cooperate with the receivers 
with  high  starting  current,  such  as  LED  fluorescent  lamps, 
ESL fluorescent lamps, electronic transformers, discharge lamps, 
etc.

Reviews: