background image

- 11 -

When the number of controlled output circuits exceeds 

12, the system can be expanded by connecting several 

AS-225D controllers in series. A sample wiring diagram is 

shown in the figure below.

Example of cascade control

According to the above scheme, any number of control-

lers can be combined.

Summary of Contents for AS-225D

Page 1: ...trol of light using a variety of setters including bell buttons motion sensors optical barriers pressure sensors etc Adjustable soft start feature soft brightening and dimming of lighting Purpose Features F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithother...

Page 2: ... brightness level when off so that the stairs are never completely dark Installation of the controller on a DIN rail Built in thermal protection The operating parameters of the AS 225D controller are set using the knobs on the front of the unit The operating status is indicated by LEDs Operator panel ...

Page 3: ...rom 3 to 30 seconds Warning This is the minimum switch on duration of the output If the UP or DOWN input is trig gered for a long time it will increase the output switch on duration accordingly DELAY Delay between switching on subsequent outputs of the controller The setting range 0 100 re fers to the set time of switching on of the output So if for example the switch on duration of a single outpu...

Page 4: ...cause the controller and the night light feature to work only at the actual low brightness level LED signalling U Controller power indication OUT Output circuit power indication OVER TEMP Signalling that the acceptable temperature inside the controller is exceeded Warning The AS 225D controller is equipped with thermal protection to prevent excessive overloading of the output circuits If the tempe...

Page 5: ... brightness level limited to 1 2 the maximum value Fast flashing Alarm temperature exceeded output bright ness level limited to 1 8 the maximum value On Persistent exceeding of the alarm temperatu re controller outputs turned off If the thermal protection is tripped normal operation is restored automatically as soon as the temperature falls to a safe level ...

Page 6: ... 6 Wiring diagram ...

Page 7: ...ton starts the cascade moving from the bottom to the top The circuits will be switched on starting from OUT 1 OUT 2 OUT 3 and so on until the last controlled output is reached Each of the outputs will be switched on for the time TIME set by the knob on the con troller The delay between switching on subsequent outputs is set on the controller with the DELAY knob Warning If the DOWN button remains p...

Page 8: ... The delay between switching on subsequ ent outputs is set on the controller with the DELAY knob Warning If the UP button remains pressed the lights remain on for the duration of the press The shutdown sequence of each output will begin when the UP button is released ON Control input Triggering the ON input causes simul taneous activation of all controlled output circuits of the controller The cir...

Page 9: ... connec tion and the power of the light source Connect the wire of the lights to the OUT terminals and connect the wire directly to the of the power supply according to the installation diagram above The maximum current of a single lamp shall not exceed 4 A while the total current of all lamps switched on at the same time shall not exceed 24 A Warning Provide a power supply unit of sufficient capa...

Page 10: ...ed with each other and with the terminals of the AS 225D controller Starting another cascade while the previous one is run ning will not interrupt the work of the first one but will start the next one in the set direction The exception here is the situation described in the next comment If during the cascade execution the last light is already switched on and at the same time an input DOWN or UP i...

Page 11: ...uits exceeds 12 the system can be expanded by connecting several AS 225D controllers in series A sample wiring diagram is shown in the figure below Example of cascade control According to the above scheme any number of control lers can be combined ...

Page 12: ...24 A maximum voltage 30 V DC input type potential free switch on duration 1 channel 3 30 s delay in switching on the next channel 0 switch on duration power consumption standby 1 W on 4 W terminal 2 5 mm screw terminals tightening torque 0 4 Nm working temperature 15 50 C dimensions 4 modules 52 5 mm mounting on TH 35 rail ingress protection IP20 Technical data ...

Page 13: ...th us F F Filipowski sp j declares that the device is in conformity with the essential requirements of the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which conformity is declared can be found at www fif com pl on the product page Warranty CE declaration E210721 ...