F&F AS-224 Manual Download Page 3

- 3 -

AS-224 can’t work with backlit buttons.

power supply

 

1-3 

relay’s power supply 21÷27 V AC/DC

control inputs

 

control input

contact

 

10 

output – COM power supply contact

 

12 

output – closing contact (active)

power supply 

21÷27 V AC/DC

maximum load current (AC-1) 

16 A

activation delay 

0.1÷0.2 s

deactivation delay (adjustable) 

0.5÷10 min.

power consumption 

0.6 W

terminal 

2.5 mm² screw terminals

tightening torque 

0.4 Nm

working temperature 

-25÷50°C

dimensions 

1 module (18 mm)

mounting 

on TH-35 rail

ingress protection 

IP20

Technial data

Summary of Contents for AS-224

Page 1: ...itch it ON again Function of counter blockade does not allow to keep the light ON in case of staircase switch blocking after blocking the pushbutton for example by match the timer will count the set time and switch OFF the lighting Next switching ON can be after removing the blockade Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 ...

Page 2: ...ls 1 3 in accordance with markings 4 Timer switches which were connect with parallel connect to terminal 6 and to cable which is connecting to terminal 3 5 Connect the power L to terminal 10 The supplied receivers lamps which were connect with parallel connect to terminal 12 and cable N Mounting Wiring diagram ...

Page 3: ...contact 12 output closing contact active power supply 21 27 V AC DC maximum load current AC 1 16 A activation delay 0 1 0 2 s deactivation delay adjustable 0 5 10 min power consumption 0 6 W terminal 2 5mm screw terminals tightening torque 0 4 Nm working temperature 25 50 C dimensions 1 module 18 mm mounting on TH 35 rail ingress protection IP20 Technial data ...

Page 4: ...ww fif com pl The F F products are covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of...