LM.60i 

4. Mounting 

 
 

A5911664 - GB 100503 

 

4.3. 

Electrical connections 

4.3.1.  Introduction 

 

 

Only apply power after the wiring has been connected correctly. 

 

The actuator must be correctly earthed.  

Connect the earth wire on the connection cable to the earth clamp , 
on the inside of the motor housing. 

 

Follow all the instructions on the connection diagrams. 

 

Use the correct wiring for the correct connections. 

 

Connect the LM60i to the correct supply voltage. 

 

Mount all wiring/cables so they cannot be damaged and can easily 
be replaced in the event of a malfunction. 

 

If metal cable channels are used, Fancom advises earthing the 
channel at Begin and end of the channel, and as often as possible 
at other points. 

Limit the length of the signal cables as much as possible; 

Separate heavy current and weak current cables. Crossings are 
allowed. 

Observe all regulations of the electricity company

 

Summary of Contents for LM.60i

Page 1: ...LM 60i Manual GB...

Page 2: ...ed English version of the manual For current product installation and operation information please contact the customer service and or technical service departments of the appropriate Fancom subsidiar...

Page 3: ...ctions 10 4 3 3 Optional print connections 11 4 3 4 Reversing the rotational direction 11 5 Extra possibilities LM 60i 12 5 1 Pre defined position independent control 12 6 Operation 13 6 1 Switch 13 6...

Page 4: ...ting the limit switches 22 10 4 Step 2 Adjusting CLOSED position 24 10 5 Step 3 Adjusting OPEN position 26 10 6 Step 4 Adjusting PREDEFINED position 27 10 7 Step 5 Ending adjusting 27 Appendix 1 Table...

Page 5: ...M 60i Satisfies the conditions set out in 1 The Low Voltage directive 2006 95 EC According to EN 61010 2 The Machine directive 2006 42 EC Winches motor driven NEN EN 14492 1 2006 3 The EMC directive 2...

Page 6: ...tuator for further use For the user This manual also contains a section for users which contains all the information required for daily use If you have any questions please contact your local Fancom s...

Page 7: ...tation controlled via a 0 10 10 0Volt signal or as an IO net module in a Fancom IO Network As an IO net module the intelligent module can measure the temperature and take over control in the event of...

Page 8: ...capacity 175kg 50mm Min number rotations 0 8 Max number rotations 2 7 Running speed 1 2 rot min Min max stroke length 50mm 12 5 40 cm Min max stroke length 65mm 16 53 cm Manual operation Rotary switc...

Page 9: ...x12Vdc 0 8 Ah Cable reel A5450004 50mm Pipe tube connection A5459011 1 inch CE protection cover A5459007 Temperature sensor A5045011 Range 50 110 C Resolution 0 1 C Manual potentiometer on distance A5...

Page 10: ...nstructions carefully before installing and using the actuator 3 Mount the actuator in the installation before setting the installation into operation Never touch any rotating parts of the actuator 4...

Page 11: ...within reach of people or animals lower than 2 5 m above the floor a CE protection cover must be mounted over the shaft article number A5459007 It is advisable to seal all swivels after the actuator...

Page 12: ...the swivels underneath If the mounting surface is not level use the filling plates supplied 0 5 resp 1 0mm thick Ensure there is enough space to be able to remove the cover 4 2 1 Mounting the cable r...

Page 13: ...diagrams Use the correct wiring for the correct connections Connect the LM60i to the correct supply voltage Mount all wiring cables so they cannot be damaged and can easily be replaced in the event of...

Page 14: ...10 4 3 2 Print connections A E F G B C D A Operating switch E 24 Volt AC B Potentiometer W Wiper F IO Net C Limit switches G Analogue in 0 10V 10 0Vcontrol D Motor or Temp sensor IO net Connections A...

Page 15: ...Manual Override potentiometer or thermostat MAN M Power Failure PF 4 3 4 Reversing the rotational direction It may be necessary to reverse the rotational direction of the actuator To do this exchange...

Page 16: ...lue and also a setpoint and bandwidth The intelligent module will then calculate the air inlet position based on the temperature measurement and the settings In this case L will appear on the internal...

Page 17: ...ic In order to operate the actuator manually from a distance from outside the house for example during disinfection a potentiometer of 10k with switch can be connected As soon as this is activated the...

Page 18: ...ll difference on the control input between Close and Open adjustment E Error when determining a position within the control procedure Error C Controlling maximum air inlet position successful Close O...

Page 19: ...mally and is being powered by a regular 24VAC source 7 1 3 Alarms An A in the display alternated by a figure indicates an alarm The table below contains an alarm overview Alarm indication Meaning A0 B...

Page 20: ...control the LM 60i See appendix 1 for an overview of the addresses 8 1 2 Temperature measurement As IO network module the LM 60i can measure the temperature itself This value can be used by the contr...

Page 21: ...osition Adjust the LM 60i according to the described procedures see chapter 10 Adjustment procedure 8 2 The LM 60i as conventional end station 8 2 1 Addressing If the LM 60i is used as a traditional e...

Page 22: ...it does not meet the requirements the message A5 will appear on the internal display see Alarms on page 15 The battery status is also available via the I O Network allowing a control computer with th...

Page 23: ...he required position using the 5 position manual operation switch The control board has a button for this adjustment The adjacent display indicates the status Adjusting is only possible if the manual...

Page 24: ...ED position successful E Adjusting failed Repeat adjustment procedure F Adjusting accepted however the difference on the control input between CLOSED and OPEN the voltage difference between 1 and 99 i...

Page 25: ...A5911664 GB 100503 21 Attention Ensure the steel cable is wound at least once around the drum when the air inlet is fully open The minimum length of stroke from Open to Closed must be a minimum of 0 8...

Page 26: ...inlet fully to adjust the CLOSED position 4 Twist the cam disc 1 until the disc is positioned against the lower side of the roller of the handle 8 of the limit switch 9 5 Tighten the screw on the 2 ca...

Page 27: ...disc closed position 3 Worm wheel for fine tuning closed position 4 Cam disc open position 5 Screw to fix cam disc open position 6 Worm wheel for fine tuning open position 7 Potentiometer setting 8 Ro...

Page 28: ...1 appears otherwise you will access the next mode A dash will appear on the display The drive module is now in the 1 adjustment mode 3 If the air inlet is fully closed adjust the potentiometer using...

Page 29: ...10 Adjustment A5911664 GB 100503 25 Display Status action Signal too high turn potentiometer further to the left Signal too low turn potentiometer further to the right Signal OK proceed with the next...

Page 30: ...sed This dash must be in the centre of the display If the dash is not in the centre the stroke length is too short Adjusting will fail Increase the stroke length e g by reeving the cable 4 With 0 10V...

Page 31: ...il 3 appears on the display release the button as soon as 3 appears otherwise you will access the next mode 3 Press the button to confirm and check if P appears on the display Adjusting PREDIFINED suc...

Page 32: ...On Off On Off On 11 Off Off On Off On 12 On On Off Off On 13 Off On Off Off On 14 On Off Off Off On 15 Off Off Off Off On 16 On On On On Off 17 Off On On On Off 18 On Off On On Off 19 Off Off On On O...

Page 33: ...of 120 Often by jumper or dipswitch setting The first and the last I O network module must be terminated with a resistance of 120 Often by jumper or dipswitch setting Never cut the backbone cable Remo...

Page 34: ...LM 60i Appendix 3 A5911664 GB 100503 30 Appendix 3 Mountings...

Page 35: ...LM 60i Appendix 3 A5911664 GB 100503 31 1 Mounting cable reel...

Page 36: ...dix 3 A5911664 GB 100503 32 2 Mounting steel wire 2A Feed the cable through the opening 2B Place the retainer clamp at the end of the steel cable 2C VERY IMPORTANT Wind at least 1 stroke before loadin...

Page 37: ...LM 60i Appendix 3 A5911664 GB 100503 33 3 Mounting CE protection cover on cable reel...

Page 38: ...LM 60i Appendix 3 A5911664 GB 100503 34 4 Mounting pipe chain coupling 1...

Page 39: ...tmeter on distance option Max thermostat option Analog control 0 10V 10 0V or Temperature sensor option during IO net control Accu 1 Option Accu 2 Option Trafo UPS 24Vac 230Vac 230 Vac Power supply Ma...

Reviews: